34
6.3.
RFI filter
For radio interference suppression according to EN 55011, limit
value class A or B.
Assigned RFI filters for mains voltage of 400 V
Supply module type
9212
9215
9217
Mains current RFI filter
8 A
25 A
50 A
Order no. mains filter
EZF3_008A001 EZF3_025A001 EZF3_050A004
Filter for mains voltages of up to 460 V: please contact
manufacturer
6.4.
External fuses
Semiconductor protection
External fast acting fuses in the mains input protect the input
rectifier in the supply module.
Recommended semiconductor protection fuses (at mains side):
Supply module
9212
9215
9217
Mains input with
rectifier protection
FF
20A / 700V
14 x 51
FF
63A / 700V
22 x 58
FF
100A / 700V
22 x 58
Order no.
EFSFF0200ARH
EFSFF0630ARI
EFSFF1000ARI
Input cables must be protected with standard fuses adapted to the
cross-sectional area of the cables.
6.5.
System cables
Note
For best interference immunity results, cut the cables to the required length.
6.5.1. System cables for control terminal block X5
Design for
left X5 terminals
right X5 terminals
Order no.
EW00340899
EW00340898
Fehler! Es
ist nicht
möglich,
durch die
B
b it
Summary of Contents for 9212
Page 3: ...EDB9200_E GB 00375316 Antriebstechnik Operating Instructions Servo controller 9200 series ...
Page 32: ...28 5 2 Wiring with positioning control SX 1 5 2 1 Diagram 1 Mains supply ...
Page 33: ...29 5 2 2 Diagram 2 Control circuit 230V ...
Page 34: ...30 5 2 3 Diagram 3 Control circuit 24V ...
Page 35: ...31 5 2 4 Diagram 4 Control connections 9200 SX1 Ω ...
Page 36: ...32 5 2 5 Diagram 5 Control connections SX1 ...