Introduction
1 Introduction
1.1
Safety Information
DANGER!
Hazard of electrical shock! Circuit potentials are up to 480 VAC above earth ground. Avoid direct contact with the printed
circuit board or with circuit elements to prevent the risk of serious injury or fatality. Disconnect incoming power and wait 60
seconds before servicing drive. Capacitors retain charge after power is removed.
STOP!
DO NOT connect incoming power to the output motor terminals (U, V, W)! Severe damage to the PositionServo will result.
Check phase wiring (U, V, W) and thermal input (T1, T2) before powering up drive. If miswired, severe damage to the
PositionServo will result.
STOP!
Use only 10 V (peak to peak) or less resolvers (P4). Use of higher voltage resolvers may result in feedback failure and
damage to the drive.
WARNING!
Hazard of unintended operation! When the enable input remains asserted, the “Keep Alive” circuit (P5) will restart the
motor upon restoration of mains power. If this action is not desired, then remove the enable input prior to re-application
of input power.
1.2
Legal Regulations
Claim
Description
Identification Nameplate
CE Identification
Manufacturer
Lenze controllers are unambiguously designated by the
contents of the nameplate
In compliance with the EC
Low-Voltage Directive
Lenze AC Tech Corporation
630 Douglas Street
Uxbridge, MA 01569 USA
Application
as directed
E94P or E94R servo controller
• must only be operated under the conditions prescribed in these Instructions.
• are components for:
− Closed loop control of Velocity, Torque or Positioning applications with AC synchronous motors.
− installation in a machine.
− assembly with other components to form a machine.
• are electric units for installation in control cabinets or similarly enclosed housing.
• comply with the requirements of the Low-Voltage Directive.
• are not machines for the purpose of the Machinery Directive.
• are not to be used as domestic appliances, but only for industrial purposes.
Drive systems with E94P or E94R servo inverters
comply with the EMC Directive if they are installed according to the guidelines of CE-typical drive systems.
can be used for:
− operation on public and non-public mains
− operation in industrial premises and residential areas.
The user is responsible for the compliance of his application with the EC directives.
Any other use shall be deemed as inappropriate!
Liability
• The information, data, and notes in these instructions met the latest design and implementation of the drive at the time
of publication. Claims on modifications referring to controllers that have already been supplied cannot be derived from
the information, illustrations, and descriptions.
• The specifications, processes and circuitry described in these instructions are for guidance only and must be adapted to
your own specific application. Lenze does not take responsibility for the suitability of the process and circuit proposals.
• The specifications in these Instructions describe the product features without guaranteeing them.
• Lenze does not accept any liability for damage and operating interference caused by:
− Disregarding the operating instructions
− Unauthorized modifications to the controller
− Operating errors
− Improper working on and with the controller
Warranty
Warranty conditions: refer to Lenze AC Tech Terms and Conditions of Sale, document TD03.
Disposal
Material
Recycle
Dispose
Metal
•
-
Plastic
•
-
Assembled PCB’s
-
•