13433283_P94MI01D_EN
5
Technical Data
2
Technical Data
2.1
Electrical Characteristics
Single-Phase Models
Type
(1)
Mains Voltage
(2)
1~
Mains
Current
(doubler)
1~
Mains
Current
(Std.)
Rated
Output
Current
(5)
Peak
Output
Current
(6)
Output
Power
at Rated
Output
Current
(8kHz)
(8)
Leakage
Current
Power
Loss at
Rated
Output
Current
(8kHz)
(5)
Power
Loss at
Rated
Output
Current
(16 kHz)
(5)
A
A
A
A
kVA
mA
W
W
E94_020S1N_~
120V
(3)
or 240V
(4)
9.7
5.0
2.0
6
0.8
>3.5
19
21
E94_040S1N_~
15
8.6
4.0
12
1.7
29
30
E94_020S2F_~
120 / 240V
(4)
(80 V -0%...264 V +0%)
--
5.0
2.0
6
0.8
19
21
E94_040S2F_~
--
8.6
4.0
12
1.7
29
30
E94_080S2F_~
--
15.0
8.0
24
3.3
61
63
E94_100S2F_~
--
18.8
10.0
30
4.2
80
85
Single/Three-Phase Models
Type
(1)
Mains Voltage
(2)
1~
Mains
Current
3~
Mains
Current
Rated
Output
Current
(5)
Peak
Output
Current
(6)
Output
Power
at Rated
Output
Current
(8kHz)
(8)
Leakage
Current
Power
Loss at
Rated
Output
Current
(8kHz)
(5)
Power
Loss at
Rated
Output
Current
(16 kHz)
(5)
A
A
A
A
kVA
mA
W
W
E94_020Y2N_~
120 / 240V
(4)
1~ or 3~
(80 V -0%...264 V +0%)
5.0
3.0
2.0
6
0.8
>3.5
19
21
E94_040Y2N_~
8.6
5.0
4.0
12
1.7
29
30
E94_080Y2N_~
15.0
8.7
8.0
24
3.3
61
63
E94_100Y2N_~
18.8
10.9
10.0
30
4.2
80
85
E94_120Y2N_~
24.0
13.9
12.0
36
5.0
114
129
E94_180T2N_~
240V
3~
(180 V -0%...264 V +0%)
--
19.6
18.0
54
7.5
171
195
E94_020T4N_~
400 / 480V
3~
(320 V -0%...528 V +0%)
--
2.7
2.0
6
1.7
31
41
E94_040T4N_~
--
5.5
4.0
12
3.3
50
73
E94_060T4N_~
--
7.9
6.0
18
5.0
93
122
E94_090T4N_~
--
12.0
9.0
27
7.5
138
182
(1)
The first “_” equals “P” for the 940 encoder based drive or “R” for the 941 resolver based drive.
The second “_” equals “E” for incremental encoder (E94P drive) or “R” for the standard resolver (E94R drive).
The last digit “~” equals “M” for MV OnBoard and no ISO 13849-1 circuit or “S” for MV OnBoard plus the ISO 13849-1 circuit.
(2)
Mains voltage for operation on 50/60 Hz AC supplies (48 Hz -0% … 62Hz +0%).
(3)
Connection of 120VAC (70 V … 132 V) to input power terminals L1 and N on these models doubles the voltage on motor output terminals U-V-W for use
with 230VAC motors.
(4)
Connection of 120VAC or 240VAC to input power terminals L1 and L2 on these models delivers an equal voltage as maximum to motor output terminals
U-V-W allowing operation with either 120VAC or 230VAC motors.
(5)
Drive rated at 8kHz Carrier Frequency. Derate Continuous current by 17% at 16kHz.
(6)
Peak RMS current allowed for up to 2 seconds. Peak current rated at 8kHz. Derate by 17% at 16kHz.
(7)
Derate rated output current and peak output current by 2.5% for every ºC above 40ºC up to 55ºC maximum.
(8)
At 240 VAC line input for drives with suffixes “S1N”, “S2F”, “Y2N”. At 480 VAC line input for drives with suffixes “T4N”.
a.
The output power is calculated from the formula: output kVA = [(
3
) x U
LL
x I
rated
] / 1000
b.
The actual output power (kW) depends on the motor in use due to variations in motor rated voltage, rated speed and power factor, as well as
actual max operating speed and desired overload capacity.
c.
Typical max continuous power (kW) for PM servo motors run 50-70% of the kVA ratings listed.