• An AVAGO MegaRAID adapter is installed in your computer.
• The storage drives used for RAID configuration are connected to the installed AVAGO MegaRAID adapter
instead of the system board.
Storage drive requirements for RAID levels
Your computer supports the following RAID levels:
• RAID 0: striped disk array
– Consists of at least two SATA or Serial Attached SCSI (SAS) storage drives
– Supported strip size: 64 KB, 128 KB, 256 KB, 512 KB, or 1 MB
– Better performance without fault tolerance
• RAID 1: mirrored disk array
– Consists of two or four SATA or SAS storage drives
– Improved read performance and 100% redundancy
• RAID 10: striped and mirrored disk array (a combination of RAID 0 and RAID 1)
– Consists of four SATA or SAS storage drives
– Data being striped across storage drive groups
– Provides both high data transfer rates and complete data redundancy
• RAID 5: block-level striped disk array with distributed parity
– Consists of at least three SATA or SAS storage drives
– Supported strip size: 64 KB, 128 KB, 256 KB, 512 KB, or 1 MB
– Better performance and fault tolerance
– Available only on some models of AVAGO MegaRAID adapters
• RAID 6: block-level striped disk array with dual distributed parity
– Consists of at least four SATA or SAS storage drives
– Supported strip size: 64 KB, 128 KB, 256 KB, 512 KB, or 1 MB
– Better performance and fault tolerance that can stand up to loss of two storage drives
– Available only on some models of AVAGO MegaRAID adapters
Creating a RAID volume
Attention:
All the existing data stored on the selected drives will be erased while the RAID volume is being
created.
To create a RAID volume, do the following:
1. Start the Setup Utility program. See “Starting the Setup Utility program” on page 35.
2. Select
Advanced
➙
AVAGO MegaRAID Configuration Utility
and press Enter.
3. Select
Main Menu
and press Enter.
4. Select
Configuration Management
and press Enter.
5. Select
Create Virtual Drive
and press Enter.
6. Select and configure the options one by one.
a.
Select RAID Level
: You can set the RAID level to one of the following:
•
RAID0
•
RAID1
44
P520 User Guide
Summary of Contents for ThinkStation P520
Page 1: ...P520 User Guide Machine Types 30BE 30BF 30BQ and 30DC ...
Page 12: ...x P520 User Guide ...
Page 30: ...18 P520 User Guide ...
Page 46: ...34 P520 User Guide ...
Page 60: ...48 P520 User Guide ...
Page 142: ...Figure 128 Opening the PCIe card latch 130 P520 User Guide ...
Page 152: ...140 P520 User Guide ...
Page 154: ...142 P520 User Guide ...
Page 156: ...144 P520 User Guide ...
Page 164: ...152 P520 User Guide ...
Page 166: ...Mainland China RoHS Taiwan RoHS 154 P520 User Guide ...
Page 168: ...156 P520 User Guide ...
Page 170: ...158 P520 User Guide ...
Page 172: ...160 P520 User Guide ...
Page 173: ......
Page 174: ......