![Lenovo ThinkServer RD350 User Manual And Hardware Maintenance Manual Download Page 93](http://html.mh-extra.com/html/lenovo/thinkserver-rd350/thinkserver-rd350_user-manual-and-hardware-maintenance-manual_202909093.webp)
• Use any documentation that comes with the ThinkServer RAID Super Capacitor Module and follow those
instructions in addition to the instructions in this topic.
To install the ThinkServer RAID Super Capacitor Module, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 55.
3. Remove the server cover. See “Removing the server cover” on page 55.
4. Touch the static-protective package that contains the ThinkServer RAID Super Capacitor Module to
any unpainted surface on the outside of the server. Then, take the ThinkServer RAID Super Capacitor
Module out of the package.
5. Locate the place for installing the Super Capacitor Module in the server. See “Server components”
on page 23.
6. Install the Super Capacitor Module into the holder.
Figure 38. Installing the Super Capacitor Module into the holder
7. Note the orientation of the ThinkServer RAID Super Capacitor Module. Then, lower the Super Capacitor
Module and gently slide it until it is secured by the mounting studs on the chassis.
Note:
Depending on your server model, refer to one of the following illustrations below.
Figure 39. Installing the ThinkServer RAID Super Capacitor Module
8. Connect the ThinkServer RAID Super Capacitor Module to a RAID card.
What to do next:
Chapter 6
.
Replacing hardware
79
Summary of Contents for ThinkServer RD350
Page 14: ...xii ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 52: ...38 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 66: ...52 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 148: ...134 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 158: ...144 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 169: ... Low power memory states Appendix A Notices 155 ...
Page 170: ...156 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 175: ......
Page 176: ......