CAUTION:
The heat sinks and microprocessors might be very hot. Turn off the server and wait several minutes
to let the server cool before removing the server cover.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Note:
Depending on the model, your server might look slightly different from the illustrations in this topic.
To replace the system board, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 55.
3. Remove the server cover. See “Removing the server cover” on page 55.
4. Remove the cooling shroud. See “Removing the cooling shroud” on page 58.
5. Remove the system fans. See “Replacing a system fan” on page 118.
6. Record the component locations, cable connections, and cable routing in the server.
7. Remove the two riser card assemblies. See “Replacing the riser card assembly” on page 122.
8. Remove all memory modules. See “Removing a memory module” on page 66.
9. Remove the TSM Premium module if one is installed. See “Removing the TSM Premium module”
on page 68.
10. Remove the TPM if one is installed. See “Installing or removing the ThinkServer Trusted Platform
Module” on page 69.
11. Remove the SD module if one is installed. See “Removing the SD module” on page 77.
12. Remove the coin-cell battery. See “Replacing the coin-cell battery” on page 124.
13. Remove the heat sinks. See “Installing or replacing a heat sink” on page 90.
Chapter 6
.
Replacing hardware
127
Summary of Contents for ThinkServer RD350
Page 14: ...xii ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 52: ...38 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 66: ...52 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 148: ...134 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 158: ...144 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 169: ... Low power memory states Appendix A Notices 155 ...
Page 170: ...156 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 175: ......
Page 176: ......