• To work with another piece of hardware, go to the appropriate section.
• To complete the removal procedure, go to “Completing the parts replacement” on page 131. As the
hardware RAID 5 and 50 levels are not available without the RAID 500 key, you might need to reconfigure
RAID for your server. Refer to the
MegaRAID SAS Software User Guide
on the documentation DVD that
comes with your server for information about how to configure the hardware RAID.
Installing or removing the SD module
If you equip your server with an SD module, you can install up to two SD cards into the SD module for data
storage. You can purchase an SD module and SD cards from Lenovo.
For a list of ThinkServer options, go to:
http://lenovoquickpick.com/usa/home/thinkserver/rack-and-tower-server
Installing the SD module
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 53.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Note:
Use any documentation that comes with the SD module and follow those instructions in addition to
the instructions in this topic.
To install the SD module, do the following:
1. Remove all external media from the drives and turn off all attached devices and the server. Then,
disconnect all power cords from electrical outlets and disconnect all cables that are connected to
the server.
2. Prepare your server. See “Removing or extending the server from the rack cabinet” on page 55.
3. Remove the server cover. See “Removing the server cover” on page 55.
4. Remove the riser card assembly 1. See “Replacing the riser card assembly” on page 122.
5. Locate the SD module connector on the system board. See “System board components” on page 31.
Remove any parts and disconnect any cables that might impede your operation.
6. Touch the static-protective package that contains the SD module to any unpainted surface on the
outside of the server. Then, take the SD module out of the package.
Note:
Carefully handle the SD module by its edges.
7. If you have an SD card, Install it into the SD card slot on the SD module.
76
ThinkServer RD350 User Guide and Hardware Maintenance Manual
Summary of Contents for ThinkServer RD350
Page 14: ...xii ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 18: ...4 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 20: ...6 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 52: ...38 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 66: ...52 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 148: ...134 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 158: ...144 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 169: ... Low power memory states Appendix A Notices 155 ...
Page 170: ...156 ThinkServer RD350 User Guide and Hardware Maintenance Manual ...
Page 175: ......
Page 176: ......