Chapter 5. Initializing the G7052
When you supply power to the G7052, the switch initializes automatically for basic
functions.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
System Status LEDs
The following LEDs on the switch front panel indicate the overall system status:
•
Power: Steady green if the AC power cord is connected, or flashing green if the
internal power supply unit failed and the switch is powered by a Redundant
Power Supply through a DC to DC power cable.
•
Service ( ! ): Off if the system is OK, or flashing if service is required.
For additional LED indicators, see the appropriate section in
” starting on
Connecting to the Switch
Use the switch Command-Line Interface (CLI) to perform additional configuration
tasks. You can access the CLI using the serial console port or management port.
Using the Serial Console Port
You can access the switch CLI through the serial console port on the front panel of
the switch. This port uses RS-232 serial communications. Use the console cable kit
to connect the serial console port to a terminal or a computer running a terminal
emulation program.
1
2
Summary of Contents for RackSwitch G7052
Page 1: ...Lenovo RackSwitch G7052 Installation Guide ...
Page 6: ...6 G7052 Installation Guide ...
Page 14: ...14 G7052 Installation Guide ...
Page 18: ...18 G7052 Installation Guide ...
Page 28: ...28 G7052 Installation Guide ...
Page 54: ...54 G7052 Installation Guide ...
Page 68: ...68 G7052 Installation Guide ...
Page 74: ...74 G7052 Installation Guide ...
Page 76: ...76 G7052 Installation Guide ...