1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
Figure 9. Jumper blocks on the system board
Table 5. Jumper block settings
Jumper
block
Pin position
Description
Pins 1-2
These pins should have a jumper in place for normal system operation (default).
1
J8B5:
ME Force
Update
Pins 2-3
ME force update model.
Pins 1-2
BMC Firmware Force Update Mode – Disabled (default)
2
J8C1:
BMC force
update
Pins 2-3
BMC Firmware Force Update Mode – Enabled
Pins 1-2
These pins should have a jumper in place for normal system operation (default).
3
J1A1:
BIOS
recovery
Pins 2-3
The main system BIOS will not boot with these pins jumpered. The system will boot
from a bootable recovery media with a recovery BIOS image.
Pins 1-2
These pins should have a jumper in place for normal system operation (default).
4
J2D2:
CMOS clear
Pins 2-3
If these pins are jumpered, the CMOS settings will be cleared on the next reset.
These pins should not be jumpered for normal operation.
Pins 1-2
These pins should have a jumper in place for normal system operation (default).
5
J2D1:
Password
clear
Pins 2-3
If these pins are jumpered, administrator and user passwords will be cleared on the
next reset. These pins should not be jumpered for normal operation.
36
ThinkServer TD230 Hardware Maintenance Manual
Summary of Contents for and 1040
Page 1: ...ThinkServer TD230 Hardware Maintenance Manual Machine Types 1027 1029 1039 and 1040 ...
Page 2: ......
Page 3: ...ThinkServer TD230 Hardware Maintenance Manual Machine Types 1027 1029 1039 and 1040 ...
Page 16: ...10 ThinkServer TD230 Hardware Maintenance Manual ...
Page 20: ...14 ThinkServer TD230 Hardware Maintenance Manual ...
Page 44: ...38 ThinkServer TD230 Hardware Maintenance Manual ...
Page 148: ...142 ThinkServer TD230 Hardware Maintenance Manual ...
Page 166: ...160 ThinkServer TD230 Hardware Maintenance Manual ...
Page 168: ...162 ThinkServer TD230 Hardware Maintenance Manual ...
Page 172: ...166 ThinkServer TD230 Hardware Maintenance Manual ...
Page 185: ......