Installing a PCI card
Attention:
Do not open your server or attempt any repair before reading and understanding the
Safety Information
and the
Warranty and Support Information
on the
ThinkServer Documentation DVD
that came with your product, and
“Guidelines” on page 39. To obtain a copy of the publications, go to:
http://www.lenovo.com/support
This section provides instructions on how to install a PCI card.
To install a PCI card, do the following:
Note:
Use any documentation that came with the PCI card and follow those instructions in addition to
the instructions in this section.
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 43.
3. Lay the server on its side for easier operation.
4. Locate an appropriate PCI card slot on the system board. See “Locating parts on the system board”
on page 33 to identify the types of PCI card slots for your server.
5. Remove the PCI card slot bracket by removing the screw that secures the bracket and then lift the
bracket out of the chassis. Save the PCI card slot bracket in the event that you later remove the PCI
card and need the bracket to cover the place.
6. Touch the static-protective package that contains the new PCI card to any unpainted surface on the
outside of the server. Then, remove the new PCI card from the package.
Note:
Carefully handle the PCI card by its edges.
Chapter 5
.
Replacing FRUs
73
Summary of Contents for and 1040
Page 1: ...ThinkServer TD230 Hardware Maintenance Manual Machine Types 1027 1029 1039 and 1040 ...
Page 2: ......
Page 3: ...ThinkServer TD230 Hardware Maintenance Manual Machine Types 1027 1029 1039 and 1040 ...
Page 16: ...10 ThinkServer TD230 Hardware Maintenance Manual ...
Page 20: ...14 ThinkServer TD230 Hardware Maintenance Manual ...
Page 44: ...38 ThinkServer TD230 Hardware Maintenance Manual ...
Page 148: ...142 ThinkServer TD230 Hardware Maintenance Manual ...
Page 166: ...160 ThinkServer TD230 Hardware Maintenance Manual ...
Page 168: ...162 ThinkServer TD230 Hardware Maintenance Manual ...
Page 172: ...166 ThinkServer TD230 Hardware Maintenance Manual ...
Page 185: ......