Page 33
TABLE 22
G60UHV−60C−110 BLOWER MOTOR PERFORMANCE
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM.
Return Air Options: Single side return air − Bold volumes require field−fabricated transition to accommodate
20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity across the filter.
Speed Switch Positions
ADJUST"
Switch
Second Stage HEAT" Speed
Second Stage COOL" Speed
Switch
Positions
1
2
3
4
1
2
3
4
Positions
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1540
725
1750
825
1945
915
2170 1025 1635
770
1760
830
1995
940
2225 1050
NORM
1385
655
1635
770
1785
845
1960
925
1485
700
1610
760
1820
860
2035
960
1230
580
1390
655
1585
750
1760
830
1310
620
1415
665
1620
765
1815
855
ADJUST"
First Stage HEAT" Speed
First Stage COOL" Speed
ADJUST"
Switch
P
iti
1
2
3
4
1
2
3
4
S
tc
Positions
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1390
655
1595
750
1785
845
1955
925
1140
540
1215
575
1370
645
1555
735
NORM
1255
590
1425
675
1615
765
1800
850
1030
485
1105
520
1245
585
1400
660
1135
535
1265
600
1435
675
1610
760
925
435
990
470
1125
530
1255
595
NOTES − The effect of static pressure included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately
70%
of the same second stage COOL speed position.
Continuous Fan Only speed is approximately
38%
of the same second stage COOL speed position − minimum 500 cfm (235 L/s).
Lennox Harmony III
t
Zone Control Applications − Minimum blower speed is 483 cfm (230 L/s).
TABLE 23
G60UHV−60C−110 BLOWER MOTOR PERFORMANCE
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM.
Return Air Options: Side return air with optional RAB return air base.
Speed Switch Positions
ADJUST"
Switch
Second Stage HEAT" Speed
Second Stage COOL" Speed
Switch
Positions
1
2
3
4
1
2
3
4
Positions
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1490
705
1680
790
1875
885
2085
985
1620
765
1735
820
1950
920
2185 1030
NORM
1340
635
1525
720
1715
810
1885
890
1470
695
1595
750
1780
840
1975
935
N/A
N/A
1350
635
1525
720
1700
805
1305
615
1400
660
1605
760
1785
845
ADJUST"
First Stage HEAT" Speed
First Stage COOL" Speed
ADJUST"
Switch
P
iti
1
2
3
4
1
2
3
4
S
tc
Positions
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1375
650
1570
740
1765
830
1935
915
1017
480
1075
510
1375
650
1540
725
NORM
1255
590
1425
670
1570
740
1750
825
1025
485
1100
520
1235
585
1385
655
N/A
N/A
1255
590
1415
665
1880
885
920
435
990
470
1000
470
1110
525
N/A − First and second stage HEAT positions shown cannot be used on this model.
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91%
of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately
70%
of the same second stage COOL speed position.
Continuous Fan Only speed is approximately
38%
of the same second stage COOL speed position − minimum 500 cfm (235 L/s).
Lennox Harmony III
t
Zone Control Applications − Minimum blower speed is 483 cfm (230 L/s).