Page 31
XP17
Table 11. Fan RPM Profiles
Fan RPM
Profile
Model Number
Stage 1
Pulse Width
Modulation
Percentage
Stage 1
Revolutions
Per Minutes
Stage 2
Pulse Width
Modulation
Percentage
Stage 2
Revolutions
Per Minutes
EDA Stage
Pulse Width
Modulation
Percentage
EDA Stage
Revolutions
Per Minutes
0
XC/XP17-024
55
400
55
400
55
400
1
XC/XP17-030
62
450
62
450
62
450
2
Not assigned
69
500
69
500
69
500
3
Not assigned
71
550
76
550
71
550
4
XC/XP17-036 and -042
83
600
83
600
83
600
5
Not assigned
90
650
90
650
90
650
6
XC/XP17-048 and -060
92
675
92
675
92
675
7
Not assigned
97
700
97
700
97
700
8
Not assigned
48
350
55
400
27
200
9
Not assigned
55
400
62
450
27
200
10
XP21-024
58
425
69
500
27
200
11
XC21-024
65
475
76
550
27
200
12
XC/XP21-036
72
525
83
600
30
225
13
Not assigned
79
575
90
650
30
225
14
XC21-048, - 060 and
XP21-048
83
600
92
675
30
225
15
XP21-060
86
625
97
700
30
225
Seven-Segment Alert and System Status
Codes
Alert codes are displayed using the seven-segment display
located on the outdoor control.
NOTE — System fault and lockout alarm code displays
takes precedence over system status (cooling, heating
stages or defrost/dehumidification).
The seven-segment will display an abnormal condition
(error code) when detected in the system. A list of the
codes are shown in table 12.
RESETTING ALERT CODES
Alert codes can be reset manually or automatically:
4.
Manual Reset
Manual reset can be achieved by one of the following
methods:
Disconnecting
R
wire from the main control's
R
terminal.
Turning the indoor unit off and back on again
After power up all existing codes are cleared.
5.
Automatic Reset
After an alert is detected, the main control continues to
monitor the unit's system and compressor operations.
When/if conditions return to normal, the alert code is
turned off automatically.
Summary of Contents for iComfort SL18XC1 Series
Page 44: ...Page 44 XP17 Figure 21 Typical XP17 Wiring XP17 XX 230 06...
Page 45: ...Page 45 XP17 Factory Wiring Diagrams Figure 22 Typical Factory Wiring XP17 XX 230 01...
Page 46: ...Page 46 XP17 Figure 23 Typical Factory Wiring XP17 XX 230 02...
Page 47: ...Page 47 XP17 Figure 24 Typical Factory Wiring XP17 XX 230 03 and 05...
Page 48: ...Page 48 XP17 Figure 25 Typical Factory Wiring XP17 XX 230 06...