Page 80
XP17
Table 18
.
HFC-410A Temperature (°F) - Pressure (Psig)
°F
Psig
°F
Psig
°F
Psig
°F
Psig
°F
Psig
°F
Psig
°F
Psig
°F
Psig
32
100.8
48
137.1
63
178.5
79
231.6
94
290.8
110
365.0
125
445.9
141
545.6
33
102.9
49
139.6
64
181.6
80
235.3
95
295.1
111
370.0
126
451.8
142
552.3
34
105.0
50
142.2
65
184.3
81
239.0
96
299.4
112
375.1
127
457.6
143
559.1
35
107.1
51
144.8
66
187.7
82
242.7
97
303.8
113
380.2
128
463.5
144
565.9
36
109.2
52
147.4
67
190.9
83
246.5
98
308.2
114
385.4
129
469.5
145
572.8
37
111.4
53
150.1
68
194.1
84
250.3
99
312.7
115
390.7
130
475.6
146
579.8
38
113.6
54
152.8
69
197.3
85
254.1
100
317.2
116
396.0
131
481.6
147
586.8
39
115.8
55
155.5
70
200.6
86
258.0
101
321.8
117
401.3
132
487.8
148
593.8
40
118.0
56
158.2
71
203.9
87
262.0
102
326.4
118
406.7
133
494.0
149
601.0
41
120.3
57
161.0
72
207.2
88
266.0
103
331.0
119
412.2
134
500.2
150
608.1
42
122.6
58
163.9
73
210.6
89
270.0
104
335.7
120
417.7
135
506.5
151
615.4
43
125.0
59
166.7
74
214.0
90
274.1
105
340.5
121
423.2
136
512.9
152
622.7
44
127.3
60
169.6
75
217.4
91
278.2
106
345.3
122
428.8
137
519.3
153
630.1
45
129.7
61
172.6
76
220.9
92
282.3
107
350.1
123
434.5
138
525.8
154
637.5
46
132.2
62
175.4
77
224.4
93
286.5
108
355.0
124
440.2
139
532.4
155
645.0
47
134.6
78
228.0
109
360.0
140
539.0
Summary of Contents for iComfort SL18XC1 Series
Page 44: ...Page 44 XP17 Figure 21 Typical XP17 Wiring XP17 XX 230 06...