background image

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE REPRESENTATIVE AND ARE NOT DRAWN TO SCALE.

3

LENNOX HEARTH PRODUCTS  •  ELITE LINEAR VIEW DIRECT-VENT GAS FIREPLACE (MODELS LDV42, LDV54)  •  INSTALLATION INSTRUCTIONS

       WARNINg 

young children should be care-

fully  supervised  when  they  are 

in the same room as the appli-

ance. Toddlers, young children 

and  others  may  be  susceptible 

to  accidental  contact  burns.  A 

physical barrier is recommended 

if there are at risk individuals in 

the house. To restrict access to 

a  fireplace  or  stove,  install  an 

adjustable  safety  gate  to  keep 

toddlers,  young  children  and 

other at risk individuals out of the 

room and away from hot surfaces.

       AVERTISSEMENT 

Les jeunes enfants devraient être 

surveillés  étroitement  lorsqu’ils 

se trouvent dans la même pièce 

que  l’appareil.  Les  tout  petits, 

les jeunes enfants ou les adultes 

peuvent  subir  des  brûlures  s’ils 

viennent en contact avec la sur-

face chaude. Il est recommandé 

d’installer une barrière physique 

si des personnes à risques habitent 

la maison.  Pour empêcher l’accès 

à un foyer ou à un poêle, installez 

une  barrière  de  sécurité;  cette 

mesure empêchera les tout petits, 

les jeunes enfants et toute autre 

personne à risque d’avoir accès à 

la pièce et aux surfaces chaudes.

Children and adults should be alerted to 

the hazards of high surface temperature 

and should stay away to avoid burns or 

clothing ignition. 

Les enfants et les adultes devraient 

être infor-més des dangers que posent 

les températures de surface élevées 

et se tenir à distance afin d’éviter des 

brûlures ou que leurs vêtements ne 

s’enflamment.

       WARNINg 

Clothing  or  other  flammable 

material should not be placed on 

or near the appliance.

       AVERTISSEMENT 

On ne devrait pas placer de vête-

ments ni d’autres matières inflam-

mables sur l’appareil ni à proximité.

       WARNINg 

Improper installation, adjustment, 

alteration, service or maintenance 

can  cause  injury  or  property 

damage. Refer to this manual. for 

assistance or additional informa-

tion consult a qualified installer, 

service agency or the gas supplier.

       WARNINg 

failure  to  comply  with  these 

installation  instructions  will 

result in an improperly installed 

and operating appliance, voiding 

its warranty.  Any change to this 

appliance  and/or  its  operating 

controls is dangerous.

       WARNINg 

Improper  installation  or  use  of 

this appliance can cause serious 

injury or death from fire, burns, 

explosion  or  carbon  monoxide 

poisoning.

DO NOT ATTEMPT TO ALTER OR MODIfy 

ThE CONSTRUCTION Of ThE APPLIANCE 

OR  ITS  COMPONENTS.  ANy  MODIfI-

CATION  OR  ALTERATION  MAy  VOID  

ThE  WARRANTy,  CERTIfICATION,  AND 

 LISTINgS Of ThIS UNIT.

       WARNINg 

Any  safety  screen  or  guard 

removed for servicing the appli-

ance must be replaced prior to 

operating the appliance.

       AVERTISSEMENT 

Tout écran ou protecteur retiré pour 

permettre l’entretien de l’appareil 

doit être remis en place avant de 

mettre l’appareil en marche.

NOTE: Installation and repair should be done 

by a qualified service person. The appliance 

should be inspected before use and at least 

annually  by  a  professional  service  person. 

More frequent cleaning may be required due 

to excessive lint from carpeting, bedding ma-

terial, et cetera. It is imperative that control 

compartments, burners, and circulating air 

passageways of the appliance be kept clean.

Remarque  :  L’installation  et  la  répara-

tion devrait être confiées à un technicien 

qualifié.  L’appareil  devrait  faire  l’objet 

d’une  inspection  par  un  technicien  pro-

fessionnel avant d’être utilisé et au moins 

une fois l’an par la suite. Des nettoyages 

plus fréquents peuvent être nécessaires 

si les tapis, la literie, et cetera produisent 

une quantité importante de pous-sière. Il 

est essentiel que les compartiments abri-

tant les commandes, les brûleurs et les 

conduits de circulation d’air de l’appareil 

soient tenus propres.

Do not use these appliances if any part has 

been under water.  Immediately call a quali-

fied,  professional  service  technician  to  in-

spect the appliance and to replace any parts 

of  the  control  system  and  any  gas  control 

which have been under water.

Ne  pas  utiliser  cet  appareil  s’il  a  été 

plongé,  même  partiellement,  dans 

l’eau. Appeler un technicien qualifié pour 

inspecter  l’appareil  et  remplacer  toute 

partie du système de commande et toute 

commande qui a été plongée dans l’eau.

Only trim kit(s) supplied by the manufacturer 

shall  be  used  in  the  installation  of  this 

appliance.

Seules les trousses de garniture fournies 

par le fabricant doivent être utilisées pour 

l’installation de cet appareil.

Provide  adequate  clearances  around  air 

openings  and  adequate  accessibility  clear-

ance for service and proper operation. Never 

obstruct  the  front  or    back  openings  of  the 

appliance.

IMPORTANT 

WARNINgS/NOTICES

Summary of Contents for ELITE LDV42N

Page 1: ...is or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Page 2: ...allation Instructions this manual Care and Operation Instructions Safety in Operation Warnings Warranty Vent restrictor assembly Remote control kit handheld remote control transmitter remote control r...

Page 3: ...proper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning Do not attempt to alter or modify the construction of the applianc...

Page 4: ...e ON OFF function only Efficiencies Fireplace Model Natural Gas Propane AFUE EnerGuide P4 AFUE EnerGuide P4 ldv42 66 7 54 2 69 6 59 4 ldv54 71 9 63 2 72 1 65 5 AFUE Annual Fuel Utilization Efficiency...

Page 5: ...with certain vent runs 16 Reinstall baffle if removed for vent restrictor installation 28 Install media 27 Install glass door 29 12 Verify appliance operation 30 Lighting instructions 31 Air shutter a...

Page 6: ...of the mantel UNPROTECTED Side Wall See Figure 6 4 for minimum clearances to unprotected side walls FINISH SURROUND IMPORTANT The factory supplied non com bustible fiber board MUST be installed aroun...

Page 7: ...fireplace the nailing flanges MUST be adjusted according to finish cleanface or surround and wall finish material thickness This is critical to ensure proper fireplace location especially if installi...

Page 8: ...or dimension information only Fireplace must be adequately framed and supp A Required frame opening width 1 2 of A horizontal centerline of fireplace and vent framing opening B Required frame opening...

Page 9: ...vertical position for cleanface finish and at 1 2 wall finish depth Cleanface Finish Nailing Flange Settings 1 Leave vertical position of nailing flanges at factory setting see Figure 9 1 DETAIL A 2 I...

Page 10: ...opane tank smaller than 100 lbs may create pressure loss and insufficient fuel delivery which can cause sooting severe delayed ignition or other malfunctions ref NPFA 58 Any damage as a result of insu...

Page 11: ...alified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Figure 11 3 Gas Stub 1 2...

Page 12: ...t all factory and field connections for gas leaks Note Even though soapy water is an effective leak test solution it is NOT recommended because soap residue can corrode pipes and fittings over time 1...

Page 13: ...against the adjoining section until fully engaged 3 Twist the section being attached CLOCK WISE running the dimples down and along the channels until seated at the ends of the channels The sections ar...

Page 14: ...L 2 1 4 2 1 0 1 2 1 2 2 2 1 4 3 2 1 6 4 t n e V f o t h g i e H s n o i t c e S t n e V f o r e b m u N s e h c n i t f 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0 0 0 0 6 6 5 0 8 2 5 7 3 3 2 1 0 0 8 0 9 5...

Page 15: ...bove appliance vent outlet VENT RUN SUPPORT REQUIREMENTS Supporting Vertical Vent Runs Note Proper venting support is very important NEVER use the fireplace to support the weight of the venting Suppor...

Page 16: ...o slide the assembly up into the vent collar as shown in Figure 16 3 The vent restrictor is held in place by fric tion only The entire vent restrictor assembly must be up inside the vent collar with n...

Page 17: ...ofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slidetheinnerflexpipeov...

Page 18: ...provided Vent Restrictor if re quired see Page 16 A 90 elbow may NOT be attached directly to the appliance collar A minimum of 6 pipe must be used between the fireplace collar and a 90 elbow For more...

Page 19: ...screw c Apply non combustible caulking silicone caulking is acceptable around entire cir cumference to ensure a water tight seal LENNOX HEARTH PRODUCTS ELITE LINEAR VIEW DIRECT VENT GAS FIREPLACE MODE...

Page 20: ...rtical Firestop Spacer must be used anywhere vent pipe passes through a combustible floor or ceiling Horizontal Firestop Spacer must be used anywhere vent pipe passes through a combustible wall For fu...

Page 21: ...termination must have a minimum 6 152 mm clearance to any overhead combustible projection less than or equal to 2 1 2 64 mm For projections greater than 2 1 2 64 mm see Figure 21 1 For additional vent...

Page 22: ...U S 12 in Canada V L B J X V A G Inside Corner Detail B C C C 18 Ventilated Soffit Horizontal Termination Detail D Exterior Wall 6 Inside Corner See Item D in the Text Below V P V O N N Q NOTE Local...

Page 23: ...Attach termination adaptor See Figure 23 2 Attach the termination adaptor provided with the termination to the vent section or telescoping vent section or elbow in the same manner as the other vent co...

Page 24: ...1PH Junction Box Field Wired Factory Wired Power Supply Unswitched CAUTION Ground supply lead must be con nected to the wire attached to the green ground screw located on the outlet box Failure to do...

Page 25: ...can turn on suddenly Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system CAUTION Propertydamagehazard Excessive heat can cause propert...

Page 26: ...is turned off The receiver beeps 2 times Low Battery Detection Remote Control The life of the Remote Control batteries depends on many factors including battery quality and number of appliance ignitio...

Page 27: ...complete combus tion sooting and poor flame quality and will void the warranty Rear Floor Section Rear Ledge Tab Side Panel Center Lower Tab Reinstall front floor section 1 See Figure 27 2 Engage lowe...

Page 28: ...allelectricitytotheappliancebeforeinstallingmedia If media is not installed according to the installation instructions flame impingement and improper combustion could occur resulting in soot This appl...

Page 29: ...tempt to substitute the materials used on these doors or replace cracked or broken glass The glass door s of this appliance must onlybereplacedasacompleteunitaspro vided by the manufacturer Do not att...

Page 30: ...re also provided on a tag attached to one of the lower door brackets When first lighting the appliance it will take a few minutes for the gas line to purge itself of air Once purging is complete the p...

Page 31: ...tools Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance...

Page 32: ...Guidelines If there is smoke or soot present first ensure that the flames are not impinging on any of the panels If the panels are properly posi tioned and a sooting condition still exists increase t...

Page 33: ...ES Make sure TOP and BOTTOM Nailing Flanges are attached to fireplace in the correct VERTI CAL position for Surround finish and the correct HORIZONTAL position for the wall finish material thickness s...

Page 34: ...rd abuts lip Combustible Wall Finish Material Top Non Combustible Fiber Board provided with fireplace Wall Stud Insulation and combustible material NOT ALLOWED in clearance zones around vent component...

Page 35: ...rez la t l commande et nettoyez la soigneuse ment pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le bo tier de la t l commande Figure B Choisissez la langue qui es...

Page 36: ...4 5VF 10 Firestop Spacer Vertical rigid 1 1 1 spacing 10 pk 96K92 SV4 5SP Support Plate Vent Sections Rigid Listed Secure Vent Components Cat Model Description 17M52 SV4 5HGS 1 TerminationGuard Square...

Page 37: ...sedflex 77L89 SFKIT24S Horiz Termination forflex with24inch 610 mm compressedflex 77L90 SFKIT36S Horiz Termination forflex with36inch 914 mm compressedflex 77L91 SFKIT48S Horiz Termination forflex wit...

Page 38: ...ever use substitute materials Use of non approved parts can result in poor performance and safety hazards and may void the warranty Parts with item numbers are illustrated on the next page Item No Des...

Page 39: ...are those listed on the previous page LENNOX HEARTH PRODUCTS ELITE LINEAR VIEW DIRECT VENT GAS FIREPLACE MODELS LDV42 LDV54 INSTALLATION INSTRUCTIONS 25 1 67 5 D B R E V 00 4 Power 120V Out Fan Aux O...

Page 40: ...eserves the right to make changes at any time without notice in design materials specifications and prices and also to discontinue colors styles and products Consult your local distributor for firepla...

Reviews: