background image

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE REPRESENTATIVE AND ARE NOT DRAWN TO SCALE.

35

Figure A 

Figure B

ATTAChINg SAfETy-IN-OPERATION  

WARNINgS

It is required that the set of safety instruction labels 

that have been furnished with the fireplace be affixed 

to the operation and control points of the fireplace. A 

safety instruction label must be affixed to the receiver 

wall switch plate where the fireplace is turned on 

and off (see 

Figure A

) and on the remote control 

handheld transmitter (see 

Figure B

). To properly 

complete the installation of this fireplace, locate the 

multi-lingual adhesive labels provided with the Care 

and Operation Instructions and proceed as follows:
1.  Locate the wall receiver that controls the fireplace 

(verify the switch operates the fireplace by turn-

ing it on and off). Clean the wall receiver plate 

thoroughly to remove any dust and oils. Affix 

the label to the surface of the plate of the wall 

receiver  that controls the fireplace (

Figure A

).  

Choose the language primarily spoken in the 

home. If unknown, affix the English language 

label.

2.  Locate  the  remote  control  transmitter  and 

clean  it  thoroughly  to  remove  any  dust  and 

oils. Affix the label to the surface of handheld 

transmitter (

Figure B

).  Choose the language 

primarily spoken in the home. If unknown, affix 

the English language label.

3.  If you are unable to locate the labels, please 

call Lennox Hearth Products or your nearest 

Lennox Hearth Products dealer to receive ad-

ditional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit 

LENNOx hEARTh PRODUCTS
1-800-9-LENNOx

Note: English is red text on clear label. French 

and Spanish are white text on black label.

APPOSITION DES MISES EN gARDE RELATIVES  

à LA SéCURITé D’UTILISATION

Il est impératif que le jeu d’étiquettes de sécurité qui ont été 

fournies avec le foyer soient collées à côté des dispositifs de 

contrôle du foyer. Une étiquette de sécurité doit être collée 

sur la plaque du récepteur mural contrôlant l’allumage du 

foyer (voir 

Figure A

) et sur le boîtier de la télécommande 

(

Figure  B

).    Pour  achever  l’installation  correcte  de  ce 

foyer, procédez comme suit avec les étiquettes adhésives 

en  langues  étrangères  fournies  avec  les  instructions 

d’utilisation et d’entretien :
1.  Repérez  le  récepteur  mural  qui  contrôle  le  foyer 

(vérifiez  que  l’interrupteur  contrôle  le  fonction -

nement  du  foyer  en  le  faisant  basculer  de  Marche 

à  Arrêt,  et  vice-versa).    Nettoyez  soigneusement  

la plaque du récepteur mural pour éliminer la poussière 

et les traces de graisse ou d’huile. Collez l’étiquette sur 

la surface de la plaque du récepteur mural qui contrôle 

le  foyer  (

Figure  A

).    Choisissez  la  langue  qui  est 

principalement parlée dans la résidence du propriétaire. 

En cas de doute, collez l’étiquette en anglais.

2.  Repérez la télécommande et nettoyez-la soigneuse-

ment  pour  éliminer  la  poussière  et  les  traces  

de graisse ou d’huile.  Collez l’étiquette sur le boîtier 

de  la  télécommande  (

Figure  B

).    Choisissez  la 

langue  qui  est  principalement  parlée  dans  la  

résidence  du  propriétaire.  En  cas  de  doute,  collez 

l’étiquette en anglais.

3.  Si  vous  ne  trouvez  pas  les  étiquettes,  veuillez  

appeler  Lennox  Hearth  Products  ou  votre  distribu-

teur  Lennox  Hearth  Products  local  pour  recevoir 

gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024 

LENNOx hEARTh PRODUCTS
1-800-9-LENNOx

Remarque : Le texte anglais est rouge sur un support 

transparent. Le texte français et espagnol est blanc sur un 

support noir.

COLOCACIóN DE ADVERTENCIAS DE 

SEgURIDAD EN OPERACIóN

Se requiere que el juego de etiquetas de instrucciones  

de seguridad que se incluyeron con la chimenea se 

coloque en los puntos de operación y control de la 

misma. Se debe colocar una etiqueta de instrucciones 

de seguridad en la placa del interruptor de pared  

del receptor desde el cual se enciende y se apaga  

la chimenea (ver la 

Figura A

) y en el transmisor de 

control remoto (ver la 

Figura B

). Para completar 

correctamente  la  instalación  de  esta  chimenea, 

encuentre  las  etiquetas  adhesivas  multilingües  

incluidas  con  las  instrucciones  de  cuidado  y 

operación y haga lo siguiente:
1.  Identifique el receptor de pared que controla la 

chimenea (verifique que el interruptor opera la 

chimenea encendiéndola y apagándola). Limpie  

bien la placa del receptor de pared para quitar el 

polvo y aceite. Pegue la etiqueta en la superficie 

de la placa del receptor de pared que controla la 

chimenea (

Figura A

).

 

Seleccione el idioma que 

más se habla en la casa. Si no sabe cuál es, use 

la etiqueta en inglés.

2.  Identifique  el  transmisor  de  control  remoto  y 

límpielo bien para quitar el polvo y aceite. Pegue 

la etiqueta en la superficie del transmisor (

Figura 

B

). Seleccione el idioma que más se habla en la 

casa. Si no sabe cuál es, use la etiqueta en inglés.

3.  Si  no  puede  encontrar  las  etiquetas,  sírvase 

llamar a Lennox Hearth Products o al distribuidor 

de Lennox Hearth Products más cercano para  

recibir etiquetas de instrucciones de seguridad 

adicionales gratuitas. 
Juego de etiquetas de repuesto - Nº de cat. H8024 

LENNOx hEARTh PRODUCTS
1-800-9-LENNOx

Nota: La etiqueta en inglés es transparente con 

texto rojo. Las etiquetas en francés y español son 

negras con texto blanco.

ATTAChINg SAfETy-IN-OPERATION WARNINgS
It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a 

critical step in informing consumers of safe operation of this appliance.

SAfETy LABEL DIAgRAMS   /   DIAgRAMMES DES éTIqUETTES DE SéCURITé   /   DIAgRAMAS DE ETIqUETAS DE SEgURIDAD

REMOTE

OFF

ON

LENNOX HEARTH PRODUCTS  •  ELITE LINEAR VIEW DIRECT-VENT GAS FIREPLACE (MODELS LDV42, LDV54)  •  INSTALLATION INSTRUCTIONS

ATTAChINg WARNINg 

LABELS

Summary of Contents for ELITE LDV42N

Page 1: ...is or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Page 2: ...allation Instructions this manual Care and Operation Instructions Safety in Operation Warnings Warranty Vent restrictor assembly Remote control kit handheld remote control transmitter remote control r...

Page 3: ...proper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning Do not attempt to alter or modify the construction of the applianc...

Page 4: ...e ON OFF function only Efficiencies Fireplace Model Natural Gas Propane AFUE EnerGuide P4 AFUE EnerGuide P4 ldv42 66 7 54 2 69 6 59 4 ldv54 71 9 63 2 72 1 65 5 AFUE Annual Fuel Utilization Efficiency...

Page 5: ...with certain vent runs 16 Reinstall baffle if removed for vent restrictor installation 28 Install media 27 Install glass door 29 12 Verify appliance operation 30 Lighting instructions 31 Air shutter a...

Page 6: ...of the mantel UNPROTECTED Side Wall See Figure 6 4 for minimum clearances to unprotected side walls FINISH SURROUND IMPORTANT The factory supplied non com bustible fiber board MUST be installed aroun...

Page 7: ...fireplace the nailing flanges MUST be adjusted according to finish cleanface or surround and wall finish material thickness This is critical to ensure proper fireplace location especially if installi...

Page 8: ...or dimension information only Fireplace must be adequately framed and supp A Required frame opening width 1 2 of A horizontal centerline of fireplace and vent framing opening B Required frame opening...

Page 9: ...vertical position for cleanface finish and at 1 2 wall finish depth Cleanface Finish Nailing Flange Settings 1 Leave vertical position of nailing flanges at factory setting see Figure 9 1 DETAIL A 2 I...

Page 10: ...opane tank smaller than 100 lbs may create pressure loss and insufficient fuel delivery which can cause sooting severe delayed ignition or other malfunctions ref NPFA 58 Any damage as a result of insu...

Page 11: ...alified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Figure 11 3 Gas Stub 1 2...

Page 12: ...t all factory and field connections for gas leaks Note Even though soapy water is an effective leak test solution it is NOT recommended because soap residue can corrode pipes and fittings over time 1...

Page 13: ...against the adjoining section until fully engaged 3 Twist the section being attached CLOCK WISE running the dimples down and along the channels until seated at the ends of the channels The sections ar...

Page 14: ...L 2 1 4 2 1 0 1 2 1 2 2 2 1 4 3 2 1 6 4 t n e V f o t h g i e H s n o i t c e S t n e V f o r e b m u N s e h c n i t f 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0 0 0 0 6 6 5 0 8 2 5 7 3 3 2 1 0 0 8 0 9 5...

Page 15: ...bove appliance vent outlet VENT RUN SUPPORT REQUIREMENTS Supporting Vertical Vent Runs Note Proper venting support is very important NEVER use the fireplace to support the weight of the venting Suppor...

Page 16: ...o slide the assembly up into the vent collar as shown in Figure 16 3 The vent restrictor is held in place by fric tion only The entire vent restrictor assembly must be up inside the vent collar with n...

Page 17: ...ofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slidetheinnerflexpipeov...

Page 18: ...provided Vent Restrictor if re quired see Page 16 A 90 elbow may NOT be attached directly to the appliance collar A minimum of 6 pipe must be used between the fireplace collar and a 90 elbow For more...

Page 19: ...screw c Apply non combustible caulking silicone caulking is acceptable around entire cir cumference to ensure a water tight seal LENNOX HEARTH PRODUCTS ELITE LINEAR VIEW DIRECT VENT GAS FIREPLACE MODE...

Page 20: ...rtical Firestop Spacer must be used anywhere vent pipe passes through a combustible floor or ceiling Horizontal Firestop Spacer must be used anywhere vent pipe passes through a combustible wall For fu...

Page 21: ...termination must have a minimum 6 152 mm clearance to any overhead combustible projection less than or equal to 2 1 2 64 mm For projections greater than 2 1 2 64 mm see Figure 21 1 For additional vent...

Page 22: ...U S 12 in Canada V L B J X V A G Inside Corner Detail B C C C 18 Ventilated Soffit Horizontal Termination Detail D Exterior Wall 6 Inside Corner See Item D in the Text Below V P V O N N Q NOTE Local...

Page 23: ...Attach termination adaptor See Figure 23 2 Attach the termination adaptor provided with the termination to the vent section or telescoping vent section or elbow in the same manner as the other vent co...

Page 24: ...1PH Junction Box Field Wired Factory Wired Power Supply Unswitched CAUTION Ground supply lead must be con nected to the wire attached to the green ground screw located on the outlet box Failure to do...

Page 25: ...can turn on suddenly Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system CAUTION Propertydamagehazard Excessive heat can cause propert...

Page 26: ...is turned off The receiver beeps 2 times Low Battery Detection Remote Control The life of the Remote Control batteries depends on many factors including battery quality and number of appliance ignitio...

Page 27: ...complete combus tion sooting and poor flame quality and will void the warranty Rear Floor Section Rear Ledge Tab Side Panel Center Lower Tab Reinstall front floor section 1 See Figure 27 2 Engage lowe...

Page 28: ...allelectricitytotheappliancebeforeinstallingmedia If media is not installed according to the installation instructions flame impingement and improper combustion could occur resulting in soot This appl...

Page 29: ...tempt to substitute the materials used on these doors or replace cracked or broken glass The glass door s of this appliance must onlybereplacedasacompleteunitaspro vided by the manufacturer Do not att...

Page 30: ...re also provided on a tag attached to one of the lower door brackets When first lighting the appliance it will take a few minutes for the gas line to purge itself of air Once purging is complete the p...

Page 31: ...tools Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance...

Page 32: ...Guidelines If there is smoke or soot present first ensure that the flames are not impinging on any of the panels If the panels are properly posi tioned and a sooting condition still exists increase t...

Page 33: ...ES Make sure TOP and BOTTOM Nailing Flanges are attached to fireplace in the correct VERTI CAL position for Surround finish and the correct HORIZONTAL position for the wall finish material thickness s...

Page 34: ...rd abuts lip Combustible Wall Finish Material Top Non Combustible Fiber Board provided with fireplace Wall Stud Insulation and combustible material NOT ALLOWED in clearance zones around vent component...

Page 35: ...rez la t l commande et nettoyez la soigneuse ment pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le bo tier de la t l commande Figure B Choisissez la langue qui es...

Page 36: ...4 5VF 10 Firestop Spacer Vertical rigid 1 1 1 spacing 10 pk 96K92 SV4 5SP Support Plate Vent Sections Rigid Listed Secure Vent Components Cat Model Description 17M52 SV4 5HGS 1 TerminationGuard Square...

Page 37: ...sedflex 77L89 SFKIT24S Horiz Termination forflex with24inch 610 mm compressedflex 77L90 SFKIT36S Horiz Termination forflex with36inch 914 mm compressedflex 77L91 SFKIT48S Horiz Termination forflex wit...

Page 38: ...ever use substitute materials Use of non approved parts can result in poor performance and safety hazards and may void the warranty Parts with item numbers are illustrated on the next page Item No Des...

Page 39: ...are those listed on the previous page LENNOX HEARTH PRODUCTS ELITE LINEAR VIEW DIRECT VENT GAS FIREPLACE MODELS LDV42 LDV54 INSTALLATION INSTRUCTIONS 25 1 67 5 D B R E V 00 4 Power 120V Out Fan Aux O...

Page 40: ...eserves the right to make changes at any time without notice in design materials specifications and prices and also to discontinue colors styles and products Consult your local distributor for firepla...

Reviews: