Specifications
General
Data
Model No. EL15XP1-018 EL15XP1-024 EL15XP1-030
EL15XP1-036
Nominal Tonnage
1.5
2
2.5
3
1
Sound Rating Number
71
71
71
72
Connections
(sweat)
Liquid line (o.d.) - in.
3/8
3/8
3/8
3/8
Suction line (o.d.) - in.
3/4
3/4
3/4
7/8
2
Refrigerant
R-410A charge furnished
7 lbs. 0 oz.
7 lbs. 2 oz.
7 lbs 3 oz.
8 lbs. 10 oz.
Outdoor
Coil
Net face area - sq. ft.
Outer coil
24.5
24.5
24.5
21.0
Inner coil
- - -
- - -
- - -
20.3
Tube diameter - in.
5/16
5/16
5/16
5/16
No. of rows
1
1
1
2
Fins per inch
22
22
22
22
Outdoor
Fan
Diameter - in.
22
22
22
22
No. of blades
3
3
3
3
Motor hp
1/6
1/6
1/6
1/6
Cfm
2670
2670
2890
2870
Rpm
867
867
847
839
Watts
160
160
200
205
Shipping Data - lbs. 1 pkg.
213
213
213
229
ELECTRICAL DATA
Line voltage data - 60hz
208/230V-1ph
208/230V-1ph
208/230V-1ph
208/230V-1ph
3
Maximum overcurrent protection (amps)
20
20
25
30
4
Minimum circuit ampacity
12.2
13.6
17.0
18.6
Compressor
Rated load amps
9.0
10.1
12.8
14.1
Locked rotor amps
48
52
67.8
72.2
Power factor
.98
.98
.96
.99
Outdoor Fan Motor
Full load amps
1.0
1.0
1.0
1.0
Locked rotor amps
1.9
1.9
1.9
1.9
CONTROLS
iComfort
®
E30 Smart Wi-Fi Thermostat
15S63
•
•
•
•
Remote Outdoor Temperature Sensor
X2658
•
•
•
•
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Crankcase Heater
93M04
•
•
•
Factory
Compressor Hard
Start Kit
Copeland
10J42
•
LG
88M91
•
•
•
45F08
•
•
•
•
Freezestat
3/8 in. tubing
93G35
•
•
•
•
5/8 in. tubing
50A93
•
•
•
•
58M81
•
•
•
•
5
Low Ambient Kit
54M89
•
•
•
•
Mild Weather Kit
11B97
•
•
•
•
Monitor Kit - Service Light
76F53
•
•
•
•
Outdoor
Thermostat Kit
Thermostat
10Z23
•
•
Mounting Box
31461
•
•
Refrigerant
Line Sets
L15-41-20
L15-41-30
L15-41-40
L15-41-50
•
•
•
L15-65-30
L15-65-40
L15-65-50
•
6
Snow Guard
35-1/2 x 31 in. (Canada Only)
X8780
•
•
•
•
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Sound Rating Number rated in accordance with test conditions included in AHRI Standard 270.
2
additional refrigerant charge required.
3
HACR type breaker or fuse.
4
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
5
Crankcase Heater and Freezestat are recommended with Low Ambient Kit.
6
Adds 11-1/2 inches (292 mm) to unit height.