Installation Clearances
See
NOTES
See NOTES
See NOTES
See
NOTES
CONTROL
BOX
NOTES:
Service clearance of 30 in. (762 mm) must be maintained on
one of the sides adjacent to the control box.
Clearance to one of the other three sides must be
36 in. (914 mm)
Clearance to one of the remaining two sides may be
A clearance of 24 in. must be maintained between two units.
48 in. (1219 mm) clearance required on top of unit.
Model Number Identification
Nominal SEER
Unit Type
P = Heat Pump Outdoor Unit
Refrigerant Type
X = R-410A
Nominal Cooling Capacity
018 = 1-1/2 tons
024 = 2 tons
030 = 2-1/2 tons
036 = 3 tons
042 = 3-1/2 tons
048 = 4 tons
060 = 5 tons
Revision Number
Voltage
230 = 208/230V-1ph-60hz
Product Tier
EL = Elite
®
Series
Cooling Stages
1 = Single Stage Compressor
EL
15
X
P
1
- 036
- 230
A
0 1
Ratings Revision Letter