• 67 •
152
Integer
R
0
~
1
153
Integer
R
0
~
1
154
Integer
R
0
~
1
155
Integer
R
0
~
1
156
Integer
R
0
~
1
157
Analog
R/W
8,0
22,0
35,0
158
Analog
R/W
3,0
12,0
68,0
159
Analog
R/W
30,0
38,0
68,0
160
Analog
R/W
0,0
26,0
30,0
161
Analog
R/W
0,0
19,0
30,0
162
Analog
R/W
-20,0
-20,0
50,0
163
Analog
R/W
-20,0
26,0
50,0
164
Analog
R/W
-10,0
20,0
50,0
165
Analog
R/W
-10,0
12,0
50,0
166
Analog
R/W
-20,0
-20,0
50,0
167
Analog
R/W
-20,0
-20,0
50,0
168
Analog
R/W
-20,0
10,0
50,0
169
Integer
R/W
0
0
3
170
Integer
R/W
0
0
3
171
Analog
R/W
-20,0
10,0
50,0
172
Integer
R/W
0
0
1
173
Integer
R/W
0
0
1
174
Analog
R/W
0,0
999,9
999,9
175
Integer
R
0,0
~
1,0
176
Integer
R
0,0
~
1,0
177
Integer
R
0,0
~
6,5
178
Integer
R
0,0
~
100,0
179
Integer
R
0,0
~
100,0
180
Integer
R/W
1
1
24
181
Analog
R
0,0
~
100,0
182
Integer
R
0
~
65536
183
Integer
R
0
~
65536
184
Integer
R
0
~
65536
185
Integer
R
0
~
65536
186
Integer
R
0,0
~
100,0
187
Integer
R/W
0
1000
2000
188
Integer
R/W
0
1500
2000
CLIMATIC RT_UNITARY-IOM-1508-E
BMS
@Address
R/W
DESCRIPTION
MIN
Fact.
MAX
remote control, state of the dry contact, be-1 id3
remote control, state of the dry contact, be-1 id4
control, state of cooling mode
control, state of dead zone
control, state of heating mode
economizer, temperature threshold for activation night refreshment function
control, low supply limit threshold in cooling mode
control, high supply limit threshold in heating mode
control, room temperature threshold for unloading cooling mode
control, room temperature threshold for unloading heating mode
economizer, outside lower temperature threshold for unloading frre-cooling
economizer, outside upper temperature threshold for unloading free-cooling
circuit, outside temperature threshold for unloading 50% in cooling mode
circuit, outside temperature threshold for unloading 100% in cooling mode
circuit, outside temperature threshold for unloading 50% in heating mode
circuit, outside temperature threshold for unloading 100% in heating mode
heaters, outside temperature threshold for unloading
1st heaters, bms night, set point for priority inversion starting
1st heaters, bms day, set point for priority inversion starting
1st heaters, outside temperature threshold for inversion starting
2nd heaters, bms night, set point for priority inversion starting
2nd heaters, bms day, set point for priority inversion starting
power meter, current threshold for unloaded 50% of compressors running
circuit 3 compressor 1, state
circuit 3, state of the reversing valve (heating mode)
clock, state of the schedule (zone.mode)
2nd heaters, power percentage calculated for the triac
hot water recovery, opening percentage calculated for the valve
master/slaves, setting the sub-bus
blower, speed percentage calculated for the inverter
control, count value (weight low) of operating time in cooling mode
control, count value (weight high) of operating time in cooling mode
control, count value (weight low) of operating time in heating mode
control, count value (weight high) of operating time in heating mode
cold water coil, opening percentage calculated for the valve
economizer, minimum threshold for air quality control
economizer, maximum threshold for air quality control