Description
4th
digit
3rd
digit
2nd
digit
1st
digit
R/W/Z Min
Std
Max
3131 setting
of
functionality
for
digital
input
bm
id4
Bm
‐
iD4
R/W
30
30
66
3132 setting
of
functionality
for
digital
input
bm
id7
Bm
‐
iD7
R/W
30
30
66
3133 setting
of
functionality
for
digital
input
be
‐
1
id1
Be.1
‐
iD1
R/W
30
30
66
3134 setting
of
functionality
for
digital
input
be
‐
1
id2
Be.1
‐
iD2
R/W
30
30
66
3135 setting
of
functionality
for
digital
input
be
‐
1
id3
Be.1
‐
iD3
R/W
30
30
66
3136 setting
of
functionality
for
digital
input
be
‐
1
id4
Be.1
‐
iD4
R/W
30
30
66
3141 setting
of
functionality
for
analog
input
be
‐
1
b1
Be.1
‐
B1
R/W
30
30
39
3142 setting
of
functionality
for
analog
input
be
‐
1
b2
Be.1
‐
B2
R/W
30
30
39
3143 setting
of
functionality
for
analog
input
be
‐
1
b3
Be.1
‐
B3
R/W
30
30
39
3144 setting
of
functionality
for
analog
input
be
‐
1
b4
Be.1
‐
B4
R/W
30
30
39
3145 threshold
temperature
for
4ma
external
sensor
T.
4mA
R/W
‐
99,9
‐
40
99,9
3146 threshold
temperature
for
20ma
external
sensor
T.
20mA
R/W
‐
99,9
80
99,9
3151 DC60/
DM60
Configuration
Remote
R/W
0
0
1
3152 selecting
the
display
mode
for
set
point
(k
or
°c)
Sp
Cust.
R/W
0
0
1
3153 lower
threshold
temperature
for
set
point
customer
Low
Sp
R/W
8
17
35
3154 upper
threshold
temperature
for
set
point
customer
High
Sp
R/W
8
27
35
3155 activation
of
the
authorization
to
use
old
display
or
standard
carel
DS
Lennox
R/W
0
0
1
3171 address
of
the
unit
(bus
id)
Address
R
1
1
24
3172 setting
the
sub
‐
bus
Bus
R/W
1
1
24
3173 setting
the
master
of
the
bus
Master
R/W
0
0
24
3174 number
of
compressors
for
token
function
or
number
of
units
Number
R/W
0
0
96
3175 setting
of
functionality
Function
R/W
0
0
4
3176 activation
of
the
function
slaves
works
like
master
Together
R/W
0
0
1
3177 choice
of
outside
temperature
management
Outside
R/W
0
0
2
3178 choice
of
room
temperature
management
Room
R/W
0
0
2
3179 choice
of
air
quality
management
Air
Q.
R/W
0
0
2
3181 address
of
the
unit
(bus
id)
Address
R/W
1
1
207
3182 setting
of
the
protocol
type
Type
R/W
0
2
6
3183 configuration
of
communication
bus
speed
Baud
R/W
0
3
4
3184 watchdog
timer
Watchdog
R/W
0
0
32767
3191 management
of
set
points
Restore
R/W
0
0
5
3192 reserved
for
technicians
lennox
Tests
R/W
7
7
48
3211 choice
of
the
control
(room
temperature
or
supply)
Mode
R/W
0
0
1
3212 advanced
control
pack
configuration
Humidity
R/W
0
0
1
3213 choice
of
the
room
sensor
temperature
Room
T.
R/W
1
2
511
3214 choice
of
the
outside
sensor
temperature
Out.
T.
R/W
1
1
63
3215 choice
of
the
room
sensor
humidity
Room
Hr.
R/W
1
1
511
3216 choice
of
the
outside
sensor
humidity
Out.
Hr.
R/W
1
1
63
3217 choice
of
the
supply
air
temperature
sensor
Supply
R/W
1
1
3
Expert
Expert
Expert
Expert
Expert
Expert
Expert
Unit
Unit
Unit
Unit
Unit
Unit
Control
Configuration
Cust.
Switch
Cust.
Signal
Dc
‐
Dm
Master/Slaves
Bms
Lennox
CLIMATIC
RT_UNITARY
‐
IOM
‐
1508
‐
E
.
89
.