2.1 Creating Profiles
• In the Profile Setup, 3 individual profiles can be created, in
which all three parameters can be freely set and then saved by
pressing the e-Drive .
• The various menu items can be selected using the
controls (4)
.
Pressing the e-Drive will take you back to the Profile Setup
selection.
Perform a test welding according to the welding instructions
of the material manufacturer and the national standards or guidelines. Approve the test welding.
2. Profile setup
(see button combination)
1.9 Standby
• If the
welding nozzle (9)
is not in the welding position and no button is pressed
during a definite time, the Cool down mode will automatically start after the standby
time has passed.
The cooling down process is initiated.
• If the e-Drive is pressed before the countdown (180 seconds) has finished in
Standby mode, the display will change back to the initial state.
• For setting the standby time, (section 2.2, Standby setup)
1. Work mode
1.10 Error message
• If a malfunction occurs in the automatic hot-air
welding machine VARIMAT V2, a message will
appear on the
display (5)
, which is also pro-
vided with an error code. This code stands for
a more exact definition of the error which can be
seen in the lower list.
• In case of error 02 and error 40, separate
symbols are displayed
•
An acoustic warning signal will sound in the event of serious error messages
•
If the setpoint/actual welding temperature divergence is > 20 °C, an acoustic warning signal will sound
• In case of all other errors, the spanner is displayed for the service prompt
Error
Type of error
Err01
Interruption or short-circuit of the temperature probe
Err02
Heating element defective (interruption in one/both winding(s)
Err04
Triac defective (one or both triacs are defective)
Err08
Blower motor defective
Err40
Undervoltage 25% (mains voltage 75%)