![Leister VARIMAT V2 Operating Instructions Manual Download Page 27](http://html1.mh-extra.com/html/leister/varimat-v2/varimat-v2_operating-instructions-manual_1873932027.webp)
27
1. Work mode
1.3 Setting the drive speed
• The drive speed can be adapted with the Drive button . This can be set by turning
the e-Drive in 0.1 m/min. increments from 0.7 m/min. to 12.0 m/min. This setting
can be carried out with the drive switched on or off.
• If the
welding nozzle (9)
is not in the welding position, the symbol will
appear at the lower left edge of the
displays (5)
.
• The drive can be switched on by pressing the e-Drive , the following symbol
appearing. The drive speed can be adjusted directly by turning the e-Drive .
• Pressing the e-Drive again executes the Stop command, which switches off the drive. The Setpoint
display or Cool down appears on the display.
• If no entry is made by the
controls (4
) within 3 seconds, the new drive speed will be accepted.
The Setpoint display or Cool down appears on the
display (5)
.
• If the Drive button is pressed for 3 seconds, the display will change to another menu (section 1.6, Length
measurement, blower and drive counter).
• You can change to the relevant menu by pressing the Heating or Blower button.
Stop
1.4 Setting the welding temperature
• The welding temperature can be changed with the Heating button . The welding
temperature can be set in 10°C increments from 100°C to 620°C by turning the e-
Drive . The setting is accepted after 3 seconds, as long as no button is pressed
within these 3 seconds.
• If this menu is called up from the Setpoint display, heating and blower can be started
by pressing the e-Drive . Once the heating is switched on, the cool down can be
selected (section 1.8, Cooling down).
• If the Heating button is pressed within 3 seconds, the
display (5
) will change
and the mains voltage will appear below the drive. This call-up is only possible from
the Work display (section 1.2).
• The air volume is automatically reduced at a set welding temperature of 500°C and higher.
However, the user can manually adjust the air volume using the Blower button
(see section 1.5).
If a star appears after the air volume display , achievement of the welding
temperature is no longer ensured.
• You can change to the relevant menu by pressing the Drive or Blower button.