![Leister VARIMAT V2 Operating Instructions Manual Download Page 29](http://html1.mh-extra.com/html/leister/varimat-v2/varimat-v2_operating-instructions-manual_1873932029.webp)
29
1.7 Selecting
profiles
• If the display at the bottom right of the
display (5)
is activated, profiles can
be loaded by pressing the e-Drive . The display «Select Profile» then appears.
A profile can be selected by turning the e-Drive . The profiles Free Adj. 1, 2 and
3 can be defined by the user him/herself (chapter 2, Profile setup). All other profiles have
permanently assigned values and cannot be defined by the user.
• Turning the e-Drive activates left or right arrows on the
displays (5)
at the bottom.
Right arrow by pressing the e-Drive to the next page.
Left arrow by pressing the e-Drive to the previous page.
• If the Back arrow is activated by turning the e-Drive ,
you will be taken back to the menu by pressing the e-Drive , from
which the Profile menu has been selected.
Perform a test welding according to the welding instructions of
the material manufacturer and the national standards or
guidelines. Approve the test welding.
1. Work mode
1.8 Cooling
down
• If the symbol is selected by pressing the e-Drive , the menu «
Cool down
OK ?
» will appear. Pressing the e-Drive actives the symbol OK at the bottom right of
the
display (5)
, thereby initiating the cooling down process.
• During the cooling down process, the air volume is increased to 100% and the
instantaneous welding temperature displayed.
If the welding temperature of 60 °C is fallen below, the blower will continue to operate
for 2 minutes and will automatically switch off after this time
expires. The display changes to the Setpoint display.
• After pressing the e-Drive the
display (5)
shows the last set
values for blower and heating.
• If the Cool down is active, the drive can be switched on/off
manually via the Drive button
.
The Heating button and Blower button do not have any
function.