43
UNIROOF AT/ST is intended for professional use on flat roofs and sloping roofs up to 30-degree angle of inclination.
Use only original Leister spare parts and accessories because otherwise no warranty or guarantee claims can be
asserted.
Welding processes and types of materials
• Overlap welding of thermoplastic sealing sheets/elastomer sealing sheets
(ECB, modified EPDM, EVA, FPO, PIB, PMI, PO, PP, PVC, TPO)
• Overlap welding for base seams
• Edge-close welding on the roof parapet (parapet, eaves) up to 100 mm.
• Welding on the roof parapet (parapet, eaves).
• Welding widths (20, 30, 40 mm).
Any other use or any use in excess of these is considered non-intended.
2. Technical data
UNIROOF AT
100 V
UNIROOF AT
120 V
UNIROOF AT
220 – 240 V
Nominal voltage V~
100
120
230
Nominal voltage
W
1500
1800
3450
Frequency Hz
50 / 60
Temperature °C
100 – 620
Air volume
%
45 – 100
Drive m/min.
1 – 10
Emission level
L
pA
(dB)
70 (K = 3 dB)
Dimensions (L × W × H)
mm
475 × 244 × 260
Weight kg
17.5 (including 3 weights)
Mark of conformity
Protection Class I
UNIROOF ST
100 V
UNIROOF ST
120 V
UNIROOF ST
220 – 240 V
Nominal voltage V~
100
120
230
Nominal voltage
W
1500
1800
3450
Frequency Hz
50 / 60
Temperature, stepless
°C
100 – 620
Air volume, stepless
1 – 10
Drive, stepless
m/min.
0.7 – 10
Emission level
L
pA
(dB)
70 (K = 3 dB)
Dimensions (L × W × H)
mm
475 × 244 × 260
Weight kg
17.5 (including 3 weights)
Mark of conformity
Protection Class I
We continue to reserve the right to make technical changes.
1.1 Intended use
1.2 Non-intended use