TS11/TS15, Check & Adjust
81
4.3
Combined Adjustment (l, t, i, c and ATR)
Description
The combined adjustment procedure determines the following instrument errors in
one process:
Combined adjust-
ment procedure
step-by-step
The following table explains the most common settings.
l, t
Compensator longitudinal and transversal index errors
i
Vertical index error, related to the standing axis
c
Horizontal collimation error, also called line of sight error
ATR Hz
ATR zero point error for horizontal angle option
ATR V
ATR zero point error for vertical angle option
Step
Description
1.
Main Menu
:
User
\
Check & Adjust
2.
Check & Adjust Wizard
Select the option:
Check & adjust the compensator, index error, line of
sight error & automatic target pointing
3.
Next
4.
Face I measurement