162
TS11/TS15, Technical Data
7.6
PowerSearch PS
Range
Measurements at the vertical limits of the fan or under unfavourable atmospheric
conditions may reduce the maximum range. (*optimally aligned to the instrument)
Searching
Characteristics
Reflector
Range PS
[m]
[ft]
Standard prism (GPR1)
300
1000
360° prism (GRZ4, GRZ122)
300*
1000*
Mini prism (GMP101)
100
330
Machine Automation power prism (MPR122)
)
For Machine Control purposes only!
300*
1000*
Shortest measuring distance: 1.5 m
Typical search time:
<10 s
Default search area:
Hz: 400 gon, V: 40 gon
Definable search windows:
Yes
Principle:
Digital signal processing
Type: