64
TPS-System 1000-2.3.1en
© Leica
CO
IN
ID
PM
FS
SC
OC
IO
AR
RC
EG
CA
CT
BC
DF
SD
TS
IX
Measurement &
recording
The measurement dialog is of fundamental importance
in the TPS-System 1000. Using the appropriate
function keys, all of the information relevant to a
measurement can be entered. The comprehensive
functionality also covers requirements dictated by
unusual circumstances. The comprehensive flexibility
of the measurement dialog is also available for all
loadable applications but occasionally requires slight
modification.
The following basic functions are available:
- Simultaneous measurement of distance and angle,
using "ALL" for recording
- Separate distance measurement using "DIST" and
- Storage of the measurement "REC".
The horizontal circle can be oriented (Hz0) and
application programs started.
Input of various target point data under "TARGT".
Therse are:
- Entering target point numbers
- Target-point eccentricity
- Input of remarks 1 - 9
- Choosing various prisms and retro tape targets
- Defining various prism constants
- Entering values used to calculate the atmospheric
and geometrical distance corrections
- Entering the refraction coefficient
- Recalling the last point number to be recorded
- Changing the telescope face
- Entering manually-determined horizontal distances
- Incrementing the point number
- Switching from current- to other point numbers.