CO
IN
ID
PM
FS
SC
OC
IO
AR
RC
EG
CA
CT
BC
DF
SD
TS
IX
176
TPS-System 1000-2.3.1en
© Leica
Determine the compensator index error.
Simultaneous adjustment of the electronic bubble.
Determine the index error for the vertical circle
(V-index error) *
Defining of line-of-sight errors and, if required, of
tilting-axis errors *
Joint determination of the V-index errors, line-of-sight
errors and, if required, tilting-axis errors.
Determine the collimation error of the ATR1
(TCA versions only).
* depending on the setting within the "Functionality".
The option to determine the tilting-axis error does not
exist for the series 1100 instruments.
The instrument errors reported are displayed in the
sense of an error. When correcting measurements, they
are used in the sense of corrections and have the
opposite sign to the error.
Check your equipment after long storage or shipment
before using it again. If necessary, determine instrument
errors again.
F1
F2
F3
F4
F5
F6
CAL\ INSTRUMENT ERRORS
14:03
l,t
i
c/a
i/c/a ATR
HELP
actual
l compens. longit. : 0°00'37"
t compens. transv. : -0°00'34"
i V-index error
: 0°00'28"
c Hz coll. error
: 0°00'20"
a Tilting axis err : 0°00'26"