To define the ATR1 collimation error, a prism can be
accurately targeted at a distance of about 100 m. The
target must lie within ±9° (±10 gon) of the horizontal
plane. The procedure is analogous to that of
determining the V-index error.
Activates the calibration procedure (Refer to display on
page 176). The ATR1 target recognition is
automatically switched on. This fact is shown by the
symbol. The display shows the current horizontal
and vertical ATR1 collimation errors.
CAL\ATR COLLIM. ERRORS
14:03
MEAS
YES
F1
F2
F3
F4
F5
F6
HELP
Aim accurately at a target
positioned at a dist. > 100 m
Hz
:
73°25'36"
V
:
88°45'14"
Determ. c/i :
NO
I
The two-axis compensator is turned off automatically
when determining the ATR1 collimation error.
This fact is shown by the
symbol.
or
Starts the calibration.
CAL\ ATR COLLIM. ERRORS
14:03
COLL
F1
F2
F3
F4
F5
F6
HELP
I
actual
ATR Hz-coll.error: 0°00'05"
ATR V-coll.error: 0°00'10"
Sight the prism accurately with the crosshair.
Starts the measuring procedure.