CO
IN
ID
PM
FS
SC
OC
IO
AR
RC
EG
CA
CT
BC
DF
SD
TS
IX
© Leica
TPS-System 1000-2.3.1en
189
Motorized instruments automatically change face
directly after performing the initial measurement.
The user need only perform any fine aiming
necessary.
If the differences between the horizontal and vertical
angles do not exceed ±27' ( ±0.5 gon ), the display
shows that it is ready to measure. The user is made
aware by an acoustic signal that the
key is
redefined as "OK".
TELESCOPE POSITION
14:03
Hz- and V-positioning:
Set direction(s) to zero.
∆
Hz
:
0°00'00"
∆
V
:
0°00'00"
ABORT
OK
F1
F2
F3
F4
F5
F6
HELP
Confirms readiness to measure and the display changes
as follows.
CAL\TILTING-AXIS ERROR
14:03
Aim accurately at the same
target in other face.
Hz
:
193°19'24"
V
:
269°08'45"
MEAS
F1
F2
F3
F4
F5
F6
HELP
Sight the target accurately.
Performs the second measurement of the horizontal
angle.
II