Working with Reference Line
233
Field
Description of Field
Pos Check
•
Yes
or
No
. Allows a check to be made on the horizontal coordi-
nate difference between the manually occupied staked point and
the point to be staked. If the defined Pos Limit is exceeded, the
stakeout can be repeated, skipped or stored.
Pos Limit
•
User input. Available for Pos Check=Yes. Sets the maximum hori-
zontal coordinate difference which is accepted in the position
check.
Height Check
•
Yes
or
No
. Allows a check to be made on the vertical difference
between the manually occupied staked point and the point to be
staked. If the defined Height Limit is exceeded, the stakeout can
be repeated, skipped or stored.
Height Limit
•
User input. Available for Height Check=Yes. Sets the maximum
vertical difference accepted in the height check.
Beep near Pt
•
Yes
or
No
. The RX900 beeps when the horizontal radial distance
from the current position to the point to be staked is equal to or
less than defined in Dist from Pt.
Dist from Pt
•
User input. Available for Beep near Pt=Yes. The horizontal radial
distance from the current position to the point to be staked when
a beep should be heard.