background image

Technical data

496 05

496 04

496 03

Supply voltage: 

230V 50/60Hz

120V 50/60Hz

24V AC/DC

Consumption:

ca. 0,8 W

Contact rating: 

changeover contact    16A 250V~µ    cos 

ϕ

= 1

Parallel compensation:

60VA max. 7µF

Accuracy: 

±1 s/day under typical installation conditions

Terminal capacity:

single strand                       multi strand
1,5 to 4 mm

2

1,5 to 2,5 mm

2

Program pictures: 

56

Battery reserve:

10 years

Storage ambient:

-20°C to +60°C

Working ambient:

-20°C to +55°C

Press

together.

MENU

Press all 5 buttons together.

First release button

, after 3 seconds release

all other buttons.

MENU

®

Time switch

Rex2000 w72/1

Operating instructions

SET TIME CHECK...  ON

PROG DATE NEW...OFF

SU/Wi

D/M/Y

1234567

6

24

18

12

OK

MENU

State of contact

ON
OFF

Presentation

1234567

6

24

18

12

Real time, switching time

Clr = delete switching times

Copy =  copy switching times

Summer/winter

Day/month/year

Actual day of the week

or program day

Segment display of the 

existing program

1 segment = 30 minutes

Button Menu

activates the menu or 

breaks off the process

Button moves the flash

Symbol for automatic operation

Symbol for manual override

Symbol for continuous override ON

Symbol for continuous override OFF

Button OK
confirms the input

Button minus and plus

changes the values

Reset 1

Switching program remains

Reset 2

Switching program deleted

1. Starting

2. Setting actual time

Button

activates the menu.

Select SET TIME... with button

and confirm

with button

. Confirm once more 

SET TIME with button

.

Set actual hour with buttons

and confirm

with button

.

Set actual minute with buttons

and confirm

with button

.

OK

OK

OK

OK

MENU

SET TIME

1234567

6

24

18

12

1200W    1200W     2300W      1800W       2300W       1800W   

100W         100W

1     4      2

L

N

Safety notice

This product may be installed only by a qualified electrician. Non-compliance may result in a
fire hazard or electric shocks. Before installation, read the operating instructions and observe
the product-specific requirements for the installation location. Use only original spare parts for
repair and maintenance. All Legrand products may be opened and repaired only by specially
trained Legrand personnel. Unauthorised opening and repair by other persons will invalidate
all claims for liability, replacement or warranty services. To ensure electromagnetic tolerance
as required by the provisions to identify CE- products in applicable ambits of EMV 89/336/
CE-lines, adequate protective measures have to be found for consumers of high voltage dro-
pout - current ( for example motor run devices or lamps exceeding power rating of 800W ) or
commutation – times < 24 seconds. The device contains a LiMgO2 primary cell. When the
product reaches the end of its life, this cell must be correctly removed and disposed of in
accordance with national legislation and the requirements of environmental protection.

Menu

Connection

Function

The Rex2000 D21w is a digital 7 day time switch with a circular segmented display. Up to 8 program pictures can be set. A program picture
incorporates both ON and OFF time. If no button is pressed for 60 seconds during programming the time switch goes back to the start positi-
on. The copying function enables program to be copied to other days. Minimum switching time is 1 minute. The switching times are protected
but can be overlaid by other programs. Programs are displayed with a minimum segment size of 30 minutes. The time and the week days are
presented digitally. The summer-/winter changeover can be programmed for hand or automatic operation.

498 32

66,4

MEN

U

OK

12

34

56

7

6

24

18

12

MEN

U

OK

12

34

56

7

6

24

18

12

38

044 09

GB

Mains failure

Mains failure will be displayed by no
U
. Buttons are inoperative.
Reset is possible.

NT 291842/04

Summary of Contents for 496 03

Page 1: ...erden anderenfalls besteht Brand gefahr oder Gefahr eines elektrischen Schlages Vor der Installation die Bedienungsanleitung lesen den produktspezifischen Montageort beachten und nur Originalzubeh r b...

Page 2: ...l bernimmt die Schaltuhr wieder das Ein und Ausschalten 1234567 6 24 18 12 7 Handschalter Ein Aus 9 Dauerschaltung f r eine vorw hlbare Anzahl von Tagen 1 bis 99 Tage Mit der Taste das Symbol f r perm...

Page 3: ...s exposez un risque d incendie ou d lectrocution Avant d effectuer l installation lire la notice d utilisati on tenir compte du lieu de montage sp cifique au produit et utiliser exclusivement les acce...

Page 4: ...ectionner avec la touche le symbole pour marche permanente ou pour arr t permanent Confirmer le choix avec la touche R gler le nombre des jours avec les touches Confirmer avec la touche Terminer pr ma...

Page 5: ...electrician Non compliance may result in a fire hazard or electric shocks Before installation read the operating instructions and observe the product specific requirements for the installation locati...

Page 6: ...permanent ON or for permanent OFF with the key Acknowledge selection with the key Adjust the number of days with the keys Acknowledge with the key Premature termination of the continuous switch Select...

Page 7: ...tie de gebruiksaanwijzing lezen de productspeci fieke montage locatie in acht nemen en alleen originele toebehoren gebruiken Alle producten van Legrand mogen uitsluitend door speciaal getrainde Legran...

Page 8: ...ning AAN UIT 9 Continuschakeling voor een selecteerbaar aantal dagen 1 tot 99 dagen Met de toets het symbool voor permanent In of permanent Uit selecteren Met de toets de keuze bevestigen Met de toets...

Page 9: ...icista in caso contrario ci si espone al peri colo di incendio o di scosse elettriche Prima di procedere all installazione leggere le istruzioni per l uso attenersi al luogo di montaggio specifico al...

Page 10: ...i preselezionabile da 1 a 99 giorni Selezionare con il tasto il simbolo per l inserimento continuo del comando oppure per il disinserimento continuo del medesimo Confermare la selezione con il tasto I...

Page 11: ...ible haber le do y enten dido las instrucciones para el servicio asimismo se tiene que tener en cuenta y examinar el lugar de montaje espec fico para el producto y que solamente se deben utilizar acce...

Page 12: ...el s mbolo para encendido permanente o el s mbolo para apagado permanente Confirmar la selecci n con el bot n Con los botones regular el n mero de d as Confirmar la con el bot n Apagado prematuro del...

Page 13: ...lleres af en elektriker da der i modsat fald er fare for brand eller elek trisk st d L s betjeningsvejledningen f r installation v r opm rksom p det produktspecifik ke monteringssted og anvend udelukk...

Page 14: ...ling i et forudbestemt antal dage 1 til 99 dage Med tasten v lges symbolet for permanent IND eller symbolet for permanent UD Bekr ft valget med tasten Indstil antal dage med tasterne Bekr ft valget me...

Page 15: ...nen saa asentaa t m n tuotteen sill muutoin voi synty tulipalon tai s hk iskun vaara Ennen kuin asennat tuotteen lue k ytt ohje noudata tuotekohtaista asen nuspaikkaa ja k yt vain alkuper isi lis tarv...

Page 16: ...itaan symboli tilalle jatkuvasti P ll tai tilalle jatkuvasti p lt Pois N pp imell kuitataan valinta N pp imill asetetaan p ivien lukum r Kuitataan n pp imell Kestokytkenn n ennenaikainen lopettaminen...

Page 17: ...k Hvis ikke er det fare for brann og elektris ke st t Les bruksanvisningen f r installering Velg et monteringssted som oppfyller de pro duktspesifikke betingelsene og bruk kun originalt tilbeh r Produ...

Page 18: ...forvalg av antall dager 1 til 99 dager Velg med tast symbolet o for permanent P eller for permanent Av Bekreft med tast Still inn antall dager med tastene Bekreft med tast For tidligere avslutting av...

Page 19: ...1 4 2 L N S kerhetsf reskrifter Denna produkt f r endast installeras av beh rig elektriker Om s inte sker finns det risk f r brand eller d dlig elchock L s bruksanvisningen f re installationen och se...

Page 20: ...tal dagar 1 till 99 dagar V lj symbolen f r permanentkoppling P eller permanentkoppling AV med knappen Bekr fta valet med knappen St ll in antalet dagar med knapparna Bekr fta med knappen Avsluta perm...

Page 21: ...gem espec fico ao produto e utilizar somente acess rios originais Todos os produ tos da Legrand dever o ser abertos e reparados exclusivamente por funcion rios especialmente qualificados A abertura ou...

Page 22: ...s previamente Com a tecla seleccione o s mbolo para permanente Ligado ou para permanente Desligado Com a tecla confirme a programa o Com as teclas ajuste o n mero dos dias Confirme com a tecla Termina...

Page 23: ...K E 1234567 6 24 18 12 H Clr Copy K H M H E 1 30 MENU A A EITOYP IA AY H OK Reset 1 T Reset 2 A 1 2 P T E SET TIME E SET TIME P P OK OK OK OK MENU SET TIME 1234567 6 24 18 12 1200W 1200W 2300W 1800W...

Page 24: ...K 1234567 6 24 18 12 6 E T E PROG E TIME CHECK E O FrEE O MENU OK OK OK MENU TIME CHECK ON 1234567 6 24 18 12 1234567 6 24 18 12 24 00 2 ON OFF 1 ON OFF ON OFF 99 ON OFF 98 ON OFF 8 M E O E 1234567 6...

Reviews: