Leader Evaporator Springtech MicRO Reverse Osmosis System Manual YEAR: 2017
Page: 36
2.
Insert the bottom vessel caps into the vessels and secure with the clamps.
3.
Inspect and replace the membrane (brine) seal, if necessary on each
membrane. Lubricate the seals with permeate or non-chlorinated well or
spring water.
Replacement of Membrane Seal
When replacing a membrane seal, the seal must be installed correctly. The seal is “U” shaped. The “U” must be
positioned so it faces the incoming side of the membrane. See the diagram below.
4.
Insert a membrane into vessel #1 (vessel #1 if a single membrane system).
The end with the seal will go into the vessel last and the seal will be at the
top of the vessel when in place. Use caution when installing the membrane
– ensure the seal remains in the grooves of the membrane as it enters the
vessel. If necessary, lubricate the seal with permeate or non-chlorinated
well or spring water.