Leader Evaporator Springtech MicRO Reverse Osmosis System Manual YEAR: 2017
Page: 23
Adjusting V2 (Flow Valve) for Operations
V2 is adjusted for concentration output by flow or % sugar. As the valve is opened the concentrate flow increases and
the membrane pressure will decrease. The sugar% in the concentrate will be decreased. As the valve is closed the
flow of concentrate will decrease. The %sugar in the concentrate will increase.
The maximum pressure is 220 psi.
Generalized System Schematic
The following drawings represent the parts of the systems (one membrane and two membranes). In the cycle
illustrations the system will be represented as a rectangle labelled as “System”. NOTE: In all the cycle drawings, the
left side is the input side and the right side is the output side of the system.