Leader Evaporator Springtech MicRO Reverse Osmosis System Manual YEAR: 2017
Page: 27
Desugar Cycle
In this cycle the permeate is run in a concentrate cycle to flush accumulated sugar from the membranes.
Desugar Cycle Settings / Positions – also available on the Quick Start Guide
1.
Position V2 valve and the hoses as follows:
2.
Place the Pressure Switch (located in the center of the front panel) in the START (Down) position.
3.
Start the feed pump (bottom pump)
4.
Run the feed pump until most of the air has been purged from the flow meters on the front of the machine.
5.
Start the pressure pump (upper pump).
6.
Place the Pressure Switch in the RUN (Up) position.
7.
Using the valve on the top of the right side membrane, adjust to the desired flow rate.
8.
Check the sugar % coming from the concentrate hose every five minutes. Run the Desugar cycle until the
sugar % is down to approximately ½%.
9.
Run a rinse cycle (see page 28).
V2 – Leave where set during the concentration cycle.
Place the output end of the concentrate hose into the sap
tank at the end opposite of where the sap feeds to the
system.
Place the output end of the permeate hose into the
permeate tank.
Connect the input side of the feed pump to the permeate
tank.