Leader Evaporator Springtech MicRO Reverse Osmosis System Manual YEAR: 2017
Page: 26
Concentrate Cycle Settings / Positions – also available on the Quick Start Guide
1.
Position V2 valve and the hoses as follows:
2.
Place the Pressure Switch (located in the center of the front panel) in the START (Down) position.
3.
Start the feed pump (bottom pump)
4.
Run the feed pump until most of the air has been purged from the flow meters on the front of the machine.
5.
Start the pressure pump (upper pump).
6.
Place the Pressure Switch in the RUN (Up) position.
7.
Using the valve on the top of the right side membrane, adjust to the desired flow rate.
V2 – Open a minimum of ½ way to start
then adjust to the desired
concentration level or flow.
Place the output end of the concentrate hose into the
concentrate tank. If doing Recirculation, place the end of
the concentrate hose into the Sap tank.
Place the output end of the permeate hose into the
permeate tank.
Connect the input side of the strainer to the sap tank.