mc²96 Installation & Service Guide
Version: 1.0/3
56/65
5. Service Procedures
5.12
Replacing the Network Switch
The internal network switch, which distributes the ETHERNET A connections, is mounted inside the control
surface below the Channel display to the left of the Central GUI. Internally, it is located on the left of the Local IO
carrier unit:
To replace the switch, you will need to remove the upper panel from the channel bay housing the switch.
DO NOT
attempt to open the frame without first disconnecting the mains supply.
1.
Remove the upper panel from the channel bay on the left of the centre section as described
You will see the network switch as shown above.
2.
Disconnect all of the internal connectors from the front of the unit, taking note of where each one should
be fitted.
There are several RJ45 network connectors on the left plus a single power connector on the right: