mc²96 Installation & Service Guide
Version: 1.0/3
53/65
5. Service Procedures
4.
Remove the grounding cable by loosening its screw.
5.
Unplug the two signal connectors (mounted on the BayServer):
Steps 3, 4 and 5 allow the PSU block to be removed with all of its cables (power, grounding and signal).
Do
NOT
disconnect any wires other than those shown.
6.
Using a 8mm hex socket, remove the six nuts holding the PSU block in place:
Take care
NOT
to drop any nuts or washers into the desk.
7.
Remove the PSU block from the frame.
8.
Now fit the replacement and secure using the six hex nuts shown in step 6.
9.
Replace the power, signal and grounding cables (see steps 3 to 5).
10.
Replace the TFT display.
11.
When everything is back in place, re-connect the rear mains IEC power connectors, and power on.