Every 40 / 70 working hours or whenever necessary, check the dust filters Part. 1 Fig. 14. Remove them from
housing, loosen the filter-pressing blocks Part. 2 Fig. 14 and clean the filters by, first of all, banging them
on the floor (not violently), keeping the perforated side towards the floor. For more thorough cleaning, use a
compressed-air gun and blow from outside towards the inside, as shown in figure 14. When refitting the filters,
always remember to replace the black seal Part. 3 Fig. 14 on the bottom of the filter.
Make sure that the filters are always in good condition and, whenever necessary, replace them.
DUST SEALS:
Every 40 / 70 working hours, check the condition of the dust seals Part. 1 (movable) and Part. 2 (3 fixed seals)
Fig. 15 surrounding the central brush Part. 2 Fig. 4. Whenever necessary, replace these.
IMPORTANT: By replacing the seals make sure the side seals (the shortest one on the right and on
the left. in total 2) are raised off the ground of about 2 mm.
CENTRAL BRUSH:
Part. 2 Fig. 4. Every 50 / 80 working hours, or whenever necessary, check the condition of the central brush,
especially if you have picked up pieces of string, wire, etc.
To remove such items from the brush:
-
Remove the bin Part. 2 Fig. 7 .
-
Kneel down and inspect the central brush under the machine. Wearing gloves and a face mask to
protect the airways, remove any pieces of string or wire wrapped around the central brush. The 4 hooks
(eyebolts) provided can also be used to raise the machine (see Fig. 1) and perform this operation. Take
care not to stand underneath the machine.
ADJUSTMENTS AND REPLACEMENTS
CENTRAL BRUSH ADJUSTMENTS:
If the machine starts cleaning in a faulty manner or leaves dirt around, it will have to be adjusted and lowered
as followed:
-
Position lever Part. 1 Fig. 16 so that the central brush is raised.
-
Loosen screw Part. 2 Fig. 16 .
-
Lower the adjuster Part. 3 Fig. 16 by 3/4 mm or by the desired distance.
-
Secure the adjuster by tightening screw Part. 2 Fig. 16
-
Position lever Part. 1 fig. 16 above the adjuster Part. 3 fig. 16.
-
The central brush can be adjusted until the adjuster Part. 3 fig. 16 reaches the end of stroke; after this,
the brush must be replaced.
Summary of Contents for SWL R 1000 ET
Page 2: ......
Page 62: ...62 ...
Page 63: ...63 ...
Page 160: ...160 Obrázek ...
Page 161: ...161 Elektrická verze Spalovací verze Vzad Vpřed Bateriová verze ...
Page 162: ...162 Zavřeno Otevřeno Palivový ventil ...
Page 163: ...163 Mod BIN UP LIFT PLUS DSA ...
Page 169: ......
Page 170: ...cod 7 700 0576 rev 00 11 2021 ...