background image

1

WARNING

READ   AND   SAVE   THESE   INSTRUCTIONS

VIKING MODEL VEV900

EXTERIOR MOUNTED BLOWER

FOR USE WITH VIKING VWH, VIH, VBCV, VICV AND DTWN

24" TO 42" WIDE, 18" HIGH RANGE HOODS

TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:

1. Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the
manufacturer or your distributor.

2. Before servicing or cleaning unit, switch power off

at service panel and lock the service disconnect-
ing means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service
panel.

3. Installation work and electrical wiring must be done

by a qualified person(s) in accordance with all
applicable codes and standards, including fire-
rated construction codes and standards.

4. Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's guide-
line and safety standards such as those published
by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigera-
tion and Air Conditioning Engineers (ASHRAE),
and the local code authorities.

WARNING

CAUTION

1. For general ventilating use only. Do not use to

exhaust hazardous or explosive material and va-
pors.

2. To avoid motor bearing damage and noisy and/or

unbalanced impellers, keep drywall spray, con-
struction dust, etc. off power unit.

3. Please read specification label on product for

further information and requirements.

4. Electrical circuit, including speed control, (if used),

must be rated 6 AMPS minimum.

PLAN THE INSTALLATION

1. Locate the blower so the length of the duct run and

number of elbows needed are kept to a minimum.

2. Where possible, blower should be centered be-

tween wall studs or roof rafters.

3. Avoid pipes, wires, or other ductwork that may be

running through the wall.

ALL INSTALLATIONS

MODEL

VOLTS

AMPS

CFM

DUCT SIZE

VEV900

120

5.7

900

10 " DIA.

SPECIFICATIONS

INSTALLER: Leave This Manual With The Homeowner

HOMEOWNER: Use And Care Information On Page 4

5. When cutting or drilling into wall, or ceiling, do not

damage electrical wiring or other hidden utilities.

6. Ducted fans must always be vented to the out-

doors.

7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.

Blower Dimensions

28.251 x 24.75 x 7.17

Summary of Contents for VEV900

Page 1: ...bytheNationalFireProtectionAssociation NFPA and the American Society for Heating Refrigera tion and Air Conditioning Engineers ASHRAE and the local code authorities WARNING CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive material and va pors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray con struction dust etc off po...

Page 2: ...s 20 11 dia hole 20 103 8 1 dia hole 103 8 8 8 20 20 7 7 1 dia hole 91 8 91 8 REMOVE SHINGLES Roof Rafter REMOVE SHINGLES 11 dia hole Roof Rafter Pilot Pilot Hole Hole Pilot Hole OUTSIDE ROOF VIEW OUTSIDE ROOF VIEW From inside the attic space 2 Drill a PILOT HOLE up through the roof 8 from the inside edge of a ROOF RAFTER From outside on the roof 3 Measure and mark the 20 x 20 rectangle Cut and re...

Page 3: ...ore installing housing cover and screws 120 VAC LINE IN BLACK TO BLACK WHITE TO WHITE GREEN TO GREEN 1 Place a large bead of caulk on the back side of the housing along the outer edge 2 Center the blower ring in the 11 diameter hole making sure that the 1 1 4 diameter electrical wiring hole aligns with the hole in the wiring box 3 Attach blower to the wall with the six screws provided All six hole...

Page 4: ...lower to installation loca tion 3 Remove wiring box cover Remove knockouts fromthewiringbox Feed6 ofpowercablethrough openings and attach cables to wiring box with appropriate connectors 4 Wire black to black white to white and green or bare wire beneath green ground screw Replace wiring box cover 5 Attach rough in plate to the studs at the inside top of hood with 4 10 24 nuts provided 6 Connect d...

Page 5: ...oningEngineers ASHRAE et les codes des autorités locales 5 Whencuttingor ATTENTION 1 Cetappareilnedoitservirqu àlaventilationgénérale Ne l utilisez pas pour éliminer des matières ni des vapeurs dangereuses ou explosives 2 Pouréviterd endommagerlesroulementsdumoteur de déséquilibrer les pales ou de les rendre bruyantes débarrassez l appareil de la poussière de plâtre de construction etc 3 Veuillez ...

Page 6: ...rcez unAVANT TROU à travers le toit à une distance de216 mm 8 po durebordintérieurd unCHEVRON De l extérieur sur le toit 3 Mesurez et tracez un rectangle de 527 mm x 521 mm 20 po x 20 po Coupez et retirez seulement les bardeaux qui se trouvent à l intérieur de ce rectangle 4 Mesurez et tracez un ORIFICE D UN DIAMÈTRE DE 279 MM 11 PO et un ORIFICE D UN DIAMÈTRE DE 32 MM 1 PO Découpez ces orifices d...

Page 7: ...le du boîtier et les vis Figure 4 POSE DU VENTILATEUR POSES SUR LES TOITS POSE DU VENTILATEUR 1 Appliquez une large bande de produit à calfeutrer à l arrière du boîtier le long du rebord extérieur 2 Centrez l anneau de ventilateur dans le trou de 27 9 cm 11 po de diamètre en s assurant que l orifice pour le câblage électrique de 3 2 cm de diamètre 1 1 4 po coïncide avec l orifice dans le boîtier d...

Page 8: ...uvertures et fixez les câbles du boîtier de câblage aux connecteursappropriés 4 Branchezlesfilsnoirsensemble lesfilsblancsensemble puis placez le fil vert ou le fil dénudé sous la vis de borne de terre verte Replacez le couvercle du boîtier de câblage 5 Fixezlaplaqueduventilateurauxgoujonssetrouvantsur lapartiesupérieuredel intérieurdelahotteàl aidede 4 écrous no 10 24 inclus 6 Branchez le conduit...

Reviews: