background image

DESCRIPTION AND ASSEMBLY INSTRUCTIONS

(see fig. A,B,C ) * : optional

  

Main switch

  

Socket for tools up to 2200 W 

   

(outlet models)

  

ON/OFF Switch (outlet models)

  

Carrying handle

  

Motor  head

  

HEPA Filter (dry suction) 

  

Paper Filter, bag to fit directly on the suction inlet

  

Tank

  

Suction inlet

  

Tank  plug

  

Filter-retaining  disc

  

Head on tank locks

  

Handle

  

Wheels

  

Float

  

Filter (dry suction) 

  

Flexible hose

⑱ 

 

Extension Tube

  

Accessory holder(carpet accessory)

  

Floor accessory brush (dry suction)

  

Straight lance

  

Power tool adapter (outlet models)

  

Filter (liquid suction)

  

Small brush

  

Electri

cal power cord

  

Floor accessory (liquid suction)

INTENDED USE

•   This machine is intended for collection, vacuuming, 

conveying and separation of nonflammable dry dusts 

and non-flammable liquids and water-air mixtures. 

•  This dust category class L vacuum cleaner is for 

professional use and is suited for trades and 

workshops.

•   According to IEC/EN 60335-2-69, vacuum of dust 

category L may only be used for vacuuming and 

extraction of hazardous dusts with an exposition 

limit value > 1 mg/m3. 

•  This appliance is suitable for commercial use, for 

example in hotels, schools, hospitals, factories, shops, 

offices and rental bussinesses.

•   The appliance is intended for use as a wet and dry 

vacuum cleaner.

• 

 Failure to comply with the abovementioned 

conditions will lead to cancellation of the guarantee.

Restriction of use

•   DO NOT use the vacuum cleaner for combustible 

dust.

•   DO NOT use the vacuum cleaner in explosive 

atmospheres.

SYMBOLS

 CAUTION! 

It is important to be careful on safety 

grounds.

 IMPORTANT

 LOCKED

   OPEN

  IF PRESENT

  Double insulated (IF PRESENT): supplementary 

insulation is applied to the basic insulation to 

protect against electric shock in the event of 

failure of the basic insulation.

Additional Symbols Used

Wear Personal Protective Equipment (PPE). Ear, 

eye and respiratory protection must be worn.

WARNING:  This appliance contains harmful 

dust. The emptying and maintenance, including 

the removal of the collection bag, may only be execu-

ted by trained personnel wearing suitable protection 

equipment. Do not switch on until the complete filter 

system has been installed. Otherwise there is danger to 

your own health.

Class L vacuum clea-

ners are suitable to vacuum dry, non-combustible dusts 

with workplace limit values of > 1 mg/m3.

Translation of the original instructions

sound pressure level : LpA = 75 dB (A)

10

Summary of Contents for 8.666.3694

Page 1: ...NA UND TROCKENSAUGER ODKURZACZ DO PY W I CIECZY ATTENZIONE leggere le istruzioni prima dell utilizzo WARNING read the instructions carefully before use ATTENTION lire attentivement les istructions ava...

Page 2: ...2...

Page 3: ...15 6 8 10 14 9 24 13 21 22 23 18 19 20 26 17 11 12 16 7 5 25 7 7a 2 7 7a 6 11 22 7a 22 optional DESCRIZIONE E MONTAGGIO DESCRIPTION AND ASSEMBLY INSTRUCTIONS DESCRIPTIF ET MONTAGE BESCHREIBUNG UND MO...

Page 4: ...Aspirazione polveri Dry suction Aspiration poussiere Trockensaugen Zasysanie py w classe L 7 7a 22 6 11 16 E F 4...

Page 5: ...23 11 Aspirazione liquidi Liquid suction Aspiration liquides Na saugen Zasysanie cieczy G 5...

Page 6: ...polveri nocive con un valore limite di esposizione 1 mg m3 Questo apparecchio adatto anche per uso collettivo per esempio negli alberghi nelle scuole negli ospe dali nelle fabbriche nei negozi negli...

Page 7: ...garette Non aspirare materiali esplosivi combustibili come il grano carbone o altro materiale combustibile fine mente suddiviso SICUREZZA AVVERTENZE GENERALI 01 I componenti l imballaggio possono cost...

Page 8: ...pirazione Filtro aspirazione polvere Disco sostegno filtro Filtro aspirazione polvere Aspirazione liquidi vedi fig G Per l aspirazione di liquidi mettere il filtro Filtro per liquidi Disco sostegno fi...

Page 9: ...RIGINALI E MATERIALI DI CONSUMO Sostituire sempre ricambi e accessori con originali Questi sono disponibili presso il vostro rivenditore loca le Quando si ordinano pezzi di ricambio e accessori indica...

Page 10: ...l use for example in hotels schools hospitals factories shops offices and rental bussinesses The appliance is intended for use as a wet and dry vacuum cleaner Failure to comply with the abovementioned...

Page 11: ...maged it must be replaced by the manufacturer its service centres or similarly qualified people in order to avoid a hazard If an extension cord is used the plug and socket must be of watertight constr...

Page 12: ...g the filter Filter liquid suction Filter retaining disc The machine must be always kept on horizontal bases in a safe and stable way Insert the suitable filters for the proper use Never use the appli...

Page 13: ...d check whether it is suitable for further use If it has been damaged or broken replace it with an original filter GENUINE SPARES AND CONSUMABLES Always replace parts with genuine spares These are ava...

Page 14: ...ec des poussi res nocives d une valeur limite d exposition de 1mg m3 Cet appareil est indiqu par un emploi collectif par exemple dans les auberges les coles les h pitaux les usines les magasins les bu...

Page 15: ...ec un jet d eau Si l appareil doit fonctionner dans des locaux hu mides par ex dans une salle de bain ne le raccor dez qu des prises femelles prot g es par un di sjoncteur diff rentiel En cas de doute...

Page 16: ...osition 0 OFF et brancher l appareil une prise de courrant appro pri e ASPIRATION DES POUSSIERE Aspirateur de la classe de poussi res L conform ment la norme IEC EN 60335 2 69 pour aspirer sec des pou...

Page 17: ...re v rifiez qu il est en bon tat S il est cass ou endommag remplacez le par un filtre d origine PI CES D TACH ES ET CONSOMMABLES Toujours remplacer les pi ces par des pi ces d tach es de le fabricant...

Page 18: ...eingesetzt werden Dieses Ger t ist auch f r die kommerzielle Verwendung geeignet zum Beispiel in Hotels Schulen Krankenh u sern Fabriken Gesch ften B ros und im Vermietge sch ft Sie k nnen dieses Ger...

Page 19: ...alter anschlie et sein F r eventuelle Zweifel wenden Sie sich an Elektroinstallateur Sorgf ltig berpr fen ob die Netzanschlu leitung das Geh use oder andere Teile des Ger tes besch digt sind falls ja...

Page 20: ...ugen S ABB E F Zum Trockensaugen setzen Sie Papierfilter nur zum f r Trockensaugen Filter f r Trockensaugen St tzenscheibe f r Filter Dauer Filter f r Trockensaugen Na saugen S ABB G Zum Nasssaugen se...

Page 21: ...RTIKEL Verwenden Sie stets Original Ersatzteile Diese sind von Ihrem Fachh ndler erh ltlich Geben Sie bei der Be stellung von Ersatzteilen bitte stets die Nummer Ihres Staubsaugermodells an 3 752 0195...

Page 22: ...EC EN 60335 2 69 by stosowane do zasysania i odsysania niebezpiecznych dla zdrowia py w o warto ci granicznej ekspozycji wyno sz cej 1 mg m3 Urz dzenie to nadaje si r wnie do u ytkowania na du ych pow...

Page 23: ...de u ytkowanie inne ni przewidziane w niniejszej in strukcji mo e by niebezpieczne i nale y go unika U ywa chwytu narz dzia znajduj cego si na urz dze niu tylko dla urz dze wyposa onych w chwyt narz...

Page 24: ...cza do transportu Konieczne jest odpowiednie wyposa enie ochronne DPI Nauszniki gogle i maski U YTKOWANIE WA NE Wymagania dotycz ce stopnia przepuszczalno ci klasa ochrony przeciwpy owej L udokumentow...

Page 25: ...i elektrycznej wyci gaj c wtyczk z gniazdka elektrycznego przed wykonaniem jakiejkolwiek interwencji konserwacji i czyszczenia Zdemontowa filtr Potrz sn filtr Po oczyszczeniu filtra nale y sprawdzi pr...

Page 26: ...modifications and the standards EN est conforme aux directives CE et aux modifications successives ainsi qu aux normes EN entspricht folgenden EG Richtlinien einschlie lich sp teren nderungen und EN N...

Page 27: ......

Page 28: ...cod 7 300 0513 rev 00 01 2016 Lavorwash S p A via J F Kennedy 12 46020 Pegognaga MN ITALY...

Reviews: