56
INSTALLATION AND MAINTENANCE MANUAL
554515_A_PUB_DATE_1_FEB_2014.DOC
SENSIBILITY ADJUSTMENT, MACHINES 80-100-120 kg / 180-230-275 lb, FIGURE 5.6.B
1. Set a distance 12 mm / 0.47“ between the limiters (2).
2. By moving the vibration switch (4) on the holder (6) to the left, you will decrease the sensibility and to the right
you increase it (direction A). To reach the maximal permitted unbalance value it is necessary to keep
the distance of 60 mm / 2.36“ between the limiters (2) and the vibration switch (4), see the side view.
3. Moving the holder (6) with the switch left or right (direction B) you will centre the switch control element
to the distance axis between the limiters (2).
VERIFYING OF THE FUNCTION
Perform the verifying as follows:
1. Open the control panel cover.
2. Start extraction mode.
3. After reaching of the maximum RPM, carefully switch over the vibration switch by moving the flexible
control element manually.
WARNING!
DO THIS CAREFULLY TO AVOID INJURIES BY VIBRATING AND FIRM PARTS OF THE MACHINE!
AFTER YOU HAVE CHECKED THE FUNCTION, MOUNT ALL PANEL COVERS BACK TO ORIGINAL
PLACE!
!