Menu selection
Part 1 • Page 14-11
Part 1 – Operating Instructions
Rev. 4.00 December 2014
Software version 1.04
EcoRO Dia I/II (HT)
Part 1 • Ch
apter 14
HotRO I:
Hot cleaning of reverse osmosis is definied through target temperatures
during heating and cool down.
Value range:
Heating: 50…85°C / 122…185°F
Cool down: 35…40°C / 95…104°F
HotRO II:
Hot cleaning of reverse osmosis is definied through target temperatures
during heating and cool down.
Value range:
Heating: 50…85°C / 122…185°F
Cool down:
35…40°C / 95…104°F
Manual mode:
HotRO I or HotRO I+II can be activated through manual mode. In this
case, automatic mode is overwritten for this day.
Exception: If the period between manual mode and automatic mode is
so long that complete hot cleaning took place, automatic mode is still
initiated.
Value range:
20…90 min
Automatic operation:
The duration of hot cleaning can be defined for each day of the week.
Value range:
20…90 min
The command “Clear all values” can be used to clear all the
programmed data of the weekly program.
Heating cycles:
Only fully completed hot-cleaning cycles that are not interrupted
prematurely are registered by the counter.
HotRO I
Heating: XXX°F
Cool down: XXX°F
<<
+ -
OK
HotRO II
Heating: XXX°F
Cool down: XXX°F
<<
+ -
OK
(1=yes/0=no):
0
XXX XX X
Duration:: XX min
<<
+ -
OK
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Clear all values
<<
OK
Hot RO I + II
XX min
<<
OK
Clear all values?
<<
OK
Heating cycles RO
Hot RO I + II
XXX
<<
OK