Menu selection
Part 1 • Page 14-1
Part 1 – Operating Instructions
Rev. 4.00 December 2014
Software version 1.04
EcoRO Dia I/II (HT)
Part 1 • Ch
apter 14
14. Menu selection
14.1 Specifications, menu item 1
When >Menu< is selected, the key data shown are listed.
Certain program items have a separate method for display and input.
This is shown by selecting the respective menu sub-item as follows>
A) Display
and
B) Entry
When >Display< is selected, the set key data of the sub-menu can be
queried.
When >Entry< is selected, you will requested to enter an access code.
Permitted codes are:
Password 1 (default setting = 2232)
Password 2 (xxxx customer-specific)
The parameters of the respective sub-menu can be changed here.
The code is set digit by digit by using function keys >+< and >–< and is
confirmed by pressing >Enter<.
Parameters that are related to the system's functional safety and parame-
ters used by technical service personnel for checking system functions are
password-protected and may only be changed by authorized personnel.
1 Specifications
2 Prm dialysis mode
3 Auto on/off
4 Prm Standby mode
5 DI data
6 Cleaning data
7 RO start options
8 Passwords
9 Date/time
10 Choose system
11 Op. hours meter
12 HotRO
13 Service mode
14 Reserve
15 Fault history
<<
OK
The most important process parameters can be viewed in this menu item.
The corresponding information is shown on the display by selecting
the respective parameter using the arrow keys > < and > < and then
confirming selection by pressing the OK function key.
Selecting the menu item
<< Switches to the previous menu
!Changed data are transferred!
Cursor up/ Change values
Cursor down/ Change values
OK Activate selection
Cond permeate:
Displays the conductivity of the permeate in the feed pipe to the loop.
The conductivity is temperature compensated acc. ASTM D 1125-95
Water temperature:
Displays the temperature in the feed pipe to the supply tank (TISAH1)
and – with the HotRO option – in the concentrate (TISAH2)
Operating pressure RO:
(Option with
Aquaboss
®
Vision)
System pressure indication:
PI2 (concentrate, 1st stage): in bar / psi
PI3 (permeate, 1st stage): in bar / psi
PI4 (concentrate, 2nd stage): in bar / psi
Flow rate:
Volume flows
FISCAL 1 permeate feed in loop [l/h]
FISCAL 2 permeate return [l/h]
FISCAL 3 concentrate in channel [l/h]
Cond. permeate
Water temperature
Operating press. RO
Flow rate
Yield
Ov. Quant. of water
Ov. Quant. of water
Current flow
CD raw water
<<
OK