LT-3100 User & Installation Manual Rev. 1.06
System Services
Lars Thrane A/S
www.thrane.eu
Page 72 of 155
The Tracking window shown in Figure 84 illustrates the following periodic tracking configuration:
•
Time trigger: Enabled, Timer interval = 12:00 (HH:MM)
•
Distance trigger: Enabled, Distance interval = 50.0 (NM), Minimum time interval = 04:00 (HH:MM)
Last Report is indicating ‘1 min ago’ because the soft key ‘Report Now’ button has been used. The soft key
‘Report Now’ can be use
d to send additional tracking reports, if tracking has been configured in the web
server. Otherwise for this configuration, periodic tracking reports are to be sent every 12 hours / 50 NM
(minimum time interval: 4 hours), whatever is first triggered, time or distance.
If Time and/or Distance trigger have been enabled, then Mode is set to Periodic. If none of these trigger
conditions have been enabled, then Mode is set to Manual. If the Mode is configured to Manual, then only
tracking configuration Options ‘
Send report on power-
on’ (configuration parameter from the web server)
or the soft key ‘Report Now’ can activate a tracking report.
If selecting the Last Report using the Navigation key, then you will see the details of this last tracking report
sent, as illustrated in Figure 85.
NOTE
:
The LT-3100 system support configuration of periodic tracking reports using different
transport types and formats. The periodic tracking reports must be configured using the
web server, see Configuration - Tracking in
on page 117
Figure 84: Tracking submenu
Figure 85: Tracking (Last Report)
Summary of Contents for LT-3100
Page 2: ......