LT-3100 User & Installation Manual Rev. 1.06
Web server
Lars Thrane A/S
www.thrane.eu
Page 118 of 155
NOTE
:
Lars Thrane A/S has an Interface Control Document (ICD) with details describing the
following content: binary and text formats, remote management (configuration, requesting
position report, and trigger position report). In order to support the Thrane (binary) format
it is a requirement to get access to this ICD.
The trigger configuration options and intervals are summarized in Table 30.
The time and distance trigger conditions can be configured individually. A tracking report will be sent, when
a trigger condition has been met - time and/or distance. The trigger algorithm will
‘reset’ every time a
tracking report has been sent.
The time trigger condition can be configured from 1 minute (0:01) and up to 7 days (168:00). The distance
trigger condition can be configured from 0.1 NM and up to 999.0 NM. For the distance trigger condition, it
is possible to configure a Minimum time interval, which has the purpose to make sure that not too many
tracking reports are sent.
Example: If the distance interval is configured to 5.0 NM and Minimum time interval is configured to 01:00
hour, then position reports will be sent, when both requirements have been met (maximum every 1 hour).
If the speed over ground is < than 5 knots, then a tracking report will be sent every 5.0 NM. If the speed
over ground is > 5 knots, then a tracking report will be sent every 1 hour.
Under Options - Send report on power-on it is possible to configure the LT-3100 system to send a tracking
report every time the terminal is powered on.
Use the button Send report now, illustrated in Figure 156 on page 117, to overwrite the tracking algorithm
and send a tracking report instantly. Also, use the button to test the format of the tracking reports after
tracking configurations have been applied.
NOTE
:
The LT-3110 Control Unit UI display has a tracking window (MENU -> System -> Tracking),
providing tracking status overview. From this tracking window, it is possible to initiate a
periodic tracking report (if configured) or initiate a tracking message, which will be sent to
either an SMS or Email destination. For further details see
on page 71.
Trigger Configurations
Trigger
Format
Interval
Comments
Time
Time interval
HH:MM
0:01 to 168:00
Time can be configured from 0.01 (1
minute) to 168:00 (up to 7 days)
Distance
Distance interval
NM
0.1 to 999
Distance can be configured from 0.1 to
999 NM
Minimum time interval
HH:MM
0:01 to 168:00
Minimum time can be configured from
0.01 (1 minute) to 168:00 (up to 7 days)
Table 30: Web server
–