LT-3100S GMDSS User & Installation Manual Rev. 1.02
Installation and Mounting
Lars Thrane A/S
www.thrane.eu
Page 16 of 71
LT-3150S Alarm Panel
The LT-3150S Alarm Panel is designed for indoor mounting and connected to the LT-3140S Interface Unit
via a proprietary 4-wire CAN cable. The LT-3150S Alarm Panel specifications are available in
on page 58.
The LT-3150S Alarm Panel consist of the following human interface functions: DISTRESS button, DIM
button, and speaker. The LT-3150S Alarm Panel is delivered with a 25m cable attached to the unit.
The wire designation of the LT-3150S Alarm Panel is described in Table 2. The LT-3150S Alarm Panel can
only be connected to the LT-3140S Interface Unit.
See <reference> for operation of the DISTRESS button and activation of Distress Alert.
Figure 16: LT-3150S Alarm Panel
Table 2: LT-3150S Alarm Panel Interconnect details.
LT-3150S AP Interconnect Details
Wire Color
Wire Designation
White
VCC
Yellow
CAN+
Green
CAN-
Brown
GND