Configuring the UDS Using Telnet or the Serial Port
UDS200 User Guide
34
TCP Keepalive time in s
This option defines how many seconds the unit waits during a silent connection
before checking to see whether the currently connected network device is still on the
network. If the unit does not receive a response, it drops that connection.
ARP Cache timeout in s
When the unit communicates with another device on the network, it adds an entry
into its ARP table. The ARP Cache timeout option defines the number of seconds
(1-600) the unit waits before timing out an entry in this table.
Security Settings
Change these settings using Telnet or serial connections only, not Web Manager.
Note:
We recommend that you set security over the dedicated network or
over the serial setup. If you set security over the network (Telnet 9999),
someone else could capture these settings.
Caution:
Disabling both Telnet Setup and Port 77FE prevents users
from accessing the Setup Mode from the network.
Figure 5-8. Security Settings
Disable SNMP
This setting disables the SNMP protocol on the unit to prevent SNMP management
software from communicating with the UDS.
SNMP Community Name
This option changes the SNMP community name on the unit. This allows for ease of
management, and possibly some security. If someone tries to violate security but