Binary to Hexadecimal Conversions
UDS200 User Guide
67
Interface Mode Options
Interface Mode Options
Interface
Bits
Parity
Stop
Bits
Hex
RS-232C
7
No 1
48
RS-232C
7
No 2
C8
RS-232C
7
Even 1 78
RS-232C
7
Even 2 F8
RS-232C
7
Odd
1
58
RS-232C
7
Odd 2
D8
RS-232C 8
No
1
4C
RS-232C 8
No 2
CC
RS-232C 8
Even 1 7C
RS-232C 8
Even 2 FC
RS-232C 8
Odd 1
5C
RS-232C 8
Odd 2
DC
Pack Control Options
Pack Control Options
Sendcharacter
Defined by a:
Trailing
Characters
Idle Time
Force Transmit:
Send Immediately
after Sendcharacter
Hex
1-Byte Sequence
No
12ms
0
1-Byte Sequence
No
52ms
1
1-Byte Sequence
No
250ms
2
1-Byte Sequence
No
5sec
3
1-Byte Sequence
1
12ms
4
1-Byte Sequence
1
52ms
5
1-Byte Sequence
1
250ms
6
1-Byte Sequence
1
5sec
7
1-Byte Sequence
2
12ms
8
1-Byte Sequence
2
52ms
9
1-Byte Sequence
2
250ms
A
1-Byte Sequence
2
5sec
B
2-Byte Sequence
No
12ms
10
2-Byte Sequence
No
52ms
11
2-Byte Sequence
No
250ms
12
2-Byte Sequence
No
5sec
13
2-Byte Sequence
1
12ms
14
2-Byte Sequence
1
52ms
15
2-Byte Sequence
1
250ms
16
2-Byte Sequence
1
5sec
17
2-Byte Sequence
2
12ms
18
2-Byte Sequence
2
52ms
19
2-Byte Sequence
2
250ms
1A
2-Byte Sequence
2
5sec
1B