14: Application Examples
SLC™ Console Manager User Guide
202
The system administrator performs the following steps.
1.
Display the settings for device port 2 by using the
show deviceport
command.
2.
Change the serial settings to match the serial settings for the vt100 terminal by using the
baud
and
flowcontrol
parameters.
3.
Create a connection between the vt100 terminal connected to device port 2 and an outbound
telnet session to the server by using the
connect bidirection
command.
4.
At the VT100 terminal, press <return> a couple of times. The Telnet prompt from the server
displays the following message.
You can log in and interact with the SUN server at the VT100 terminal as if directly connected to
the server.
[SLC]> show deviceport port 2
___Current Device Port Settings________________________________________________
Number: 2 Name: Port-2
Modem Settings-------------------Data Settings----------IP Settings---------
Modem State: disabled Baud Rate: 9600 Telnet: disabled
Modem Mode: text Data Bits: 8 Telnet Port: 2002
Timeout Logins: disabled Stop Bits: 1 SSH: disabled
Local IP: negotiate Parity: none SSH Port: 3002
Remote IP: negotiate Flow Control: xon/xoff IP: <none>
Authentication: PAP Logins: disabled
CHAP Host: <none> Break Sequence: \x1bB
CHAP Secret: <none> Check DSR: disabled
NAT: disabled Close DSR: disabled
Dial-out Login: <none>
Dial-out Password: <none>
Dial-out Number: <none>
Dial-back Number: usernumber
Initialization Script: <none>
Logging Settings---------------------------------------------------------------
Local Logging: disabled PC Card Logging: disabled
Email Logging: disabled Log to: upper slot
Byte Threshold: 100 Max number of files: 10
Email Delay: 60 seconds Max size of files: 2048
Restart Delay: 60 seconds
Email To: <none>
Email Subject: Port%d Logging
Email String: <none>
NFS File Logging: disabled
Directory to log to: <none>
Max number of files: 10
Max size of files: 2048
[SLC]> set deviceport port 2 baud 57600 flowcontrol none
Device Port settings successfully updated.
[SLC]> connect bidirection 2 telnet 192.168.1.1
Connection settings successfully updated.
Trying 192.168.1.1...
Connected to 192.168.1.1.
Escape character is '^]'.
Sun OS 8.0
login:
Summary of Contents for SLC8
Page 49: ...6 Basic Parameters SLC Console Manager User Guide 49 Figure 6 1 Network Web Page...
Page 84: ...8 Devices SLC Console Manager User Guide 84 Figure 8 3 Device Ports Settings Page...
Page 121: ...9 PC Cards SLC Console Manager User Guide 121 Figure 9 3 PC Card Modem ISDN Page...
Page 135: ...11 Connections SLC Console Manager User Guide 135 Figure 11 5 Console Server...