LW 300 E / LW 450 E
Page A - 44
A
M A I N T E N A N C E A N D S E R V I C E
Check V-belt tension
The V-belt could lose tension during transportation. Please check the V-belt tension before starting
the compressor.
Tension V-belt
To tighten V-belt tension, loosen 4 mounting nuts of the drive motor. Use the tensioning screw to
move the electric motor until the V-belt tension is sufficient. Then, tighten mounting nuts and check
V-belt tension.
We recommend using a V-belt tension gauge.
Correct V-belt tension
Do not tension V-belt too tight. This damages bearings of compressor and motor. The V-belt should
only be tensioned until there is no noise caused by slipping during start.
Motor Type
Initial Installation
Operation after running in
Electric motors 50Hz
600 N
450 N
Electric motors 60Hz
500 N
400 N